Related Experiment Video
Updated: Jun 15, 2025

An Educational Video Demonstration of How to Prone a Critically Ill Intubated Patient
Published on: November 30, 2022
Development of Prone Position Ventilation Device and Study on the Application Effect of Combined Life Support
Yufeng Li1, Qiaoqiao Hu2, Wenjie Wang1
1Department of Intensive Care Unit Xuzhou Central Hospital, Xuzhou 221009, China.
Objective:
This study aims to evaluate a novel prone position ventilation device designed to enhance patient safety, improve comfort, and reduce adverse events, facilitating prolonged tolerance in critically ill patients.
Methods:
A randomized controlled trial was conducted on 60 critically ill patients from January 2020 to June 2023. Of which, one self-discharged during treatment and another was terminated due to decreased oxygenation, leaving an effective sample of 58 patients. Patients were allocated to either a control group receiving traditional prone positioning aids (ordinary sponge pads and pillows) or an intervention group using a newly developed adjustable prone positioning device. A subset of patients in each group also received life support technologies such as extracorporeal membrane oxygenation (ECMO) and continuous renal replacement therapy (CRRT). We assessed prone position ventilation tolerance, oxygen saturation increments postintervention, duration of prone positioning, CRRT filter lifespan, and the incidence of adverse events.
Results:
The intervention group exhibited significantly longer average tolerance to prone positioning (16.6 hours vs. 8.3 hours, P < 0.001 with a difference of 8.3 (4.4, 12.2) hours), higher increases in oxygen saturation postventilation (9% vs. 6%, P < 0.001 with a difference of 3.0 (1.5, 4.5)), and reduced time required for medical staff to position patients (11.7 min vs. 21.8 min, P < 0.001 with a difference of -10.1 (-11.9, -8.3)). Adverse events, including catheter displacement or blockage, facial edema, pressure injuries, and vomiting or aspiration, were markedly lower in the intervention group, with statistical significance (P < 0.05). In patients receiving combined life support, the intervention group demonstrated improved catheter blood drainage and extended CRRT filter longevity.
Conclusion:
The newly developed adjustable prone ventilation device significantly improves tolerance to prone positioning, enhances oxygenation, and minimizes adverse events in critically ill patients, thereby also facilitating the effective application of life support technologies.
Related Concept Videos
Mechanical Ventilation III: Noninvasive Ventilation
Noninvasive Positive-Pressure Ventilation...
Mechanical Ventilation II: Invasive Ventilation
Negative-Pressure Ventilators
Negative-pressure ventilators create a vacuum around the chest or body to draw air into the lungs, simulating breathing. This method does not require an...
Acute Respiratory Failure-V
Ensure that patients are monitored continuously for their response to therapy, including changes in...
Mechanical Ventilation I: Indication and Settings
Ventilatory Modes
There are three ventilatory modes: full support, partial support, and spontaneous. These are described below.
Full Support Modes
Full support modes include controlled mechanical ventilation, continuous mandatory...
Oxygen Delivering System II: Venturi Mask and Transtracheal Oxygen
Venturi Mask
The Venturi mask, named after the Venturi effect, is designed to deliver precise oxygen concentrations. It consists of a large tube with an oxygen inlet that narrows down, causing a pressure drop that pulls air in through adjustable side ports. The mask is a lightweight,...