Related Experiment Video
Updated: Jun 15, 2025

Halogenated Agent Delivery in Porcine Model of Acute Respiratory Distress Syndrome via an Intensive Care Unit Type Device
Published on: September 24, 2020
Inhalational Agent Dosing Behaviors of Anesthesia Practitioners Cause Variability in End-Tidal Concentrations at the
Franklin Dexter1, Richard H Epstein2, Vivian Ip3
1Anesthesia, University of Iowa, Iowa City, USA.
Introduction:
Prolonged times to tracheal extubation are intervals from the end of surgery to extubation ≥15 minutes. We examined why there are associations with the end-tidal inhalational agent concentration as a proportion of the age‑adjusted minimum alveolar concentration (MAC fraction) at the end of surgery.
Methods:
The retrospective cohort study used 11.7 years of data from one hospital. All p‑values were adjusted for multiple comparisons.
Results:
There was a greater odds of prolonged time to extubation if the anesthesia practitioner was a trainee (odds ratio 1.68) or had finished fewer than five cases with the surgeon during the preceding three years (odds ratio 1.12) (both P<0.0001). There was a greater risk of prolonged time to extubation if the MAC fraction was >0.4 at the end of surgery (odds ratio 2.66, P<0.0001). Anesthesia practitioners who were trainees and all practitioners who had finished fewer than five cases with the surgeon had greater mean MAC fractions at the end of surgery and had greater relative risks of the MAC fraction >0.4 at the end of surgery (all P<0.0001). The source for greater MAC fractions at the end of surgery was not greater MAC fractions throughout the anesthetic because the means during the case did not differ among groups. Rather, there was substantial variability of MAC fractions at the end of surgery among cases of the same anesthesia practitioner, with the mean (standard deviation) among practitioners of each practitioner's standard deviation being 0.35 (0.05) and the coefficient of variation being 71% (13%).
Conclusion:
More prolonged extubations were associated with greater MAC fractions at the end of surgery. The cause of the large MAC fractions was the substantial variability of MAC fractions among cases of each practitioner at the end of surgery. That variability matches what was expected from earlier studies, both from variability among practitioners in their goals for the MAC fraction given at the start of surgical closure and from inadequate dynamic forecasting of the timing of when surgery would end. Future studies should examine how best to reduce prolonged extubations by using anesthesia machines' display of MAC fraction and feedback control of end-tidal agent concentration.
Related Concept Videos
Inhalational Anesthetics: Overview
Endotracheal Intubation I: Procedure
The ET tube comprises various components, including a standard adaptor to attach a bag-valve-mask (BVM) or ventilator, a cuff, a pilot balloon, and radiopaque markings along its length to measure the insertion distance. The tube sizes...
Endotracheal Tube Extubation
Procedure
Extubation removes the endotracheal tube (ETT) from the patient on mechanical ventilation. It requires a well-coordinated, multidisciplinary approach involving physicians, nurses, respiratory therapists, and other healthcare professionals....
Endotracheal Intubation II: Nursing Management
1. Nursing Care of Patients Before Intubation
Before the endotracheal intubation procedure, nurses play an essential role in ensuring the process goes smoothly. The nurses must be familiar with intubation...
Oxygen Delivering System II: Venturi Mask and Transtracheal Oxygen
Venturi Mask
The Venturi mask, named after the Venturi effect, is designed to deliver precise oxygen concentrations. It consists of a large tube with an oxygen inlet that narrows down, causing a pressure drop that pulls air in through adjustable side ports. The mask is a lightweight,...
Parenteral Anesthetics: Overview