High-Resolution Drift Tube Ion Mobility Spectrometer with Ultra-Fast Polarity Switching
Moritz Hitzemann1, Ansgar T Kirk1, Martin Lippmann1
1Institute of Electrical Engineering and Measurement Technology, Department of Sensors and Measurement Technology, Leibniz Universität Hannover, Appelstr. 9A, Hannover 30167, Germany.
Abstract:
Besides safety and security applications, ion mobility spectrometry (IMS) is increasingly used in other fields such as medicine, environmental monitoring and food quality analysis. However, some applications require gas chromatographic separation before analysis by IMS. Furthermore, different compounds in the sample may form positive or negative ions during ionization and therefore simultaneous detection of both ion polarities is highly beneficial to avoid two chromatographic runs of the same sample. This can be achieved by ultra-fast polarity switching of a single drift tube IMS, allowing for quasi-simultaneous detection of both ion polarities. By using a ramped aperture voltage during the switching process, we overcome the issue of excessive displacement currents at the detector during polarity switching, which usually lead to overdriving the output signal of the high-gain transimpedance amplifier. Furthermore, mechanical aperture grid oscillations caused by polarity switching were also reduced through the ramped aperture voltage. This enables a polarity switching time of only 7 ms at a drift voltage of 8 kV and a drift length of 103 mm, leading to a high resolving power of RP = 117. Requiring 50 ms to acquire a pair of positive and negative spectrum, the IMS achieves an acquisition rate of 20 Hz. It reaches limits of detection of 20 pptv for dimethyl methylphosphonate and 40 pptv for methyl salicylate. For demonstration, different hop varieties were investigated and could be clearly differentiated by considering both, the positive and negative spectra.
More Related Videos
Related Concept Videos
Mass Analyzers: Common Types
Tandem Mass Spectrometry
Secondary fragmentations occur in the interaction cell and can be induced by various factors. Fragmentation induced by collision with inert gases, such as N2, Ar, He, etc., is called collision-induced...
Electrospray Ionization (ESI) Mass Spectrometry
ESI utilizes electrical energy to transfer ions from the liquid phase of the sample into the...
Capillary Electrophoresis: Instrumentation