Related Experiment Video
Updated: Jun 15, 2025

Optimized Griess Reaction for UV-Vis and Naked-eye Determination of Anti-malarial Primaquine
Published on: October 11, 2019
Innovative voltammetric techniques for bumadizone analysis in pharmaceutical and biological samples: emphasizing
Khadiga M Kelani1, Ragab A Said2,3, Mohammad A El-Dosoky2
1Pharmaceutical Analytical Chemistry Department, Faculty of Pharmacy, Cairo University, El-Kasr El-Aini Street, Cairo, 11562, Egypt. khadigakelani@gmail.com.
Abstract:
There are no documented electroanalytical methods for quantifying the anti-inflammatory drug bumadizone (BUM) in pharmaceutical or biological matrices. So, a new voltammetric method was developed to determine BUM at nano concentrations in pharmaceutical forms, in the presence of its alkaline degradant, and in biological fluids. Five electrodes were tested, including three nano-reduced graphene oxide (nRGO) electrodes (5%, 15%, and 20%), a carbon paste electrode (CPE), and a 10% nRGO-modified CPE. The 10% nRGO-modified electrode showed the best performance, offering high selectivity and low detection limits, with good linearity in the concentration range of 0.9 × 102 to 15 × 102 ng mL-1. Differential pulse voltammetry successfully applied this electrode for BUM determination in various samples, achieving excellent recovery without preliminary separation. The method was validated according to ICH guidelines and compared favorably to the reference method. Its environmental impact was assessed using AGREE and Eco-scale metrics in addition to the RGB algorithm, showing superior greenness and whiteness profiles due to safer solvents and lower energy consumption, along with high practical effectiveness using the BAGI metric.
More Related Videos
10:17High-throughput and Comprehensive Drug Surveillance Using Multisegment Injection-Capillary Electrophoresis-Mass Spectrometry
Published on: April 23, 2019
13:42Dry Film Photoresist-based Electrochemical Microfluidic Biosensor Platform: Device Fabrication, On-chip Assay Preparation, and System Operation
Published on: September 19, 2017
Related Concept Videos
Voltammetric Techniques: Linear-Scan (E vs Time)
Voltammetry: Overview
A voltammetric cell uses three electrodes: a working electrode, a reference electrode, and an auxiliary electrode. The redox reactions occur in the working...
Voltammetry: Stripping Methods
Anodic Stripping Voltammetry (ASV)
ASV is used to determine metals and metalloids at trace levels. It involves two steps: deposition and stripping. First, a negative potential is applied to the...
Voltammetric Techniques: Pulse Voltammetry
Voltammetric Techniques: Cyclic Voltammetry
Photoluminescence: Applications