Assessment of radiation dose values in common orthopaedic trauma examinations performed under X-ray fluoroscopy
Tristan Genetay1, Axel Gamulin2,3, Arnaud Lorimier4
1Diagnostic Department, University Hospitals of Geneva, Geneva, Switzerland.
Abstract:
This study aims to provide radiation reference levels in orthopaedic surgery. A total of 753 procedures were collected within 1 y. Categories containing several similar procedures were created based on four criteria: same anatomical area, same level of complexity, only single procedures, and at least 10 cases per category. Exposure was defined in terms of air kerma-area product, fluoroscopy time, and air kerma at the patient entrance reference point. For common procedures, median effective doses to patient were calculated using the Monte Carlo Software PCXMC. Most irradiating procedure in this study i.e. intramedullary nailing of the proximal femur was equivalent to an air kerma at the patient entrance reference point of 37.1 mGy, which is ~50 times lower than the threshold for acute deterministic effects of radiation. Optimization remains a must to reduce the dose while maintaining the image quality and reducing the likelihood of stochastic effects.
Related Concept Videos
Imaging Studies for Cardiovascular System III: X-Ray
Definition and Purpose
An X-ray, or radiograph, is a non-invasive method that uses ionizing radiation to take images of internal structures. It is mainly used in cardiac imaging to examine the heart, lungs, and major blood vessels, aiming to identify abnormalities in the heart's size, shape, and position, such as heart failure, congenital defects, and vascular...
X-ray Imaging
Radiological Investigation I: X-ray and CT
Biological Effects of Radiation
Computed Tomography
The technique was invented in the 1970s and is based on the principle that as X-rays pass through the body, they are absorbed or reflected at different levels. In the technique, a patient lies on a motorized platform while a computerized axial tomography (CAT) scanner rotates...