Related Experiment Video
Updated: May 9, 2026

A Swin Transformer-Based Model for Thyroid Nodule Detection in Ultrasound Images
Published on: April 21, 2023
From zero to hero: Harnessing transformers for biomedical named entity recognition in zero- and few-shot contexts
Miloš Košprdić1, Nikola Prodanović1, Adela Ljajić1
1Institute for Artificial Intelligence Research and Development of Serbia, Fruškogorska 1, Novi Sad, 21000, Serbia.
Abstract:
Supervised named entity recognition (NER) in the biomedical domain depends on large sets of annotated texts with the given named entities. The creation of such datasets can be time-consuming and expensive, while extraction of new entities requires additional annotation tasks and retraining the model. This paper proposes a method for zero- and few-shot NER in the biomedical domain to address these challenges. The method is based on transforming the task of multi-class token classification into binary token classification and pre-training on a large number of datasets and biomedical entities, which allows the model to learn semantic relations between the given and potentially novel named entity labels. We have achieved average F1 scores of 35.44% for zero-shot NER, 50.10% for one-shot NER, 69.94% for 10-shot NER, and 79.51% for 100-shot NER on 9 diverse evaluated biomedical entities with fine-tuned PubMedBERT-based model. The results demonstrate the effectiveness of the proposed method for recognizing new biomedical entities with no or limited number of examples, outperforming previous transformer-based methods, and being comparable to GPT3-based models using models with over 1000 times fewer parameters. We make models and developed code publicly available.
Related Concept Videos
Improving Translational Accuracy
Improving Translational Accuracy
Transformers
The iron core has a substantial relative permeability. Therefore, the magnetic field lines generated due to the current in one winding are almost entirely confined within the core, such that the same magnetic flux permeates each turn of both...
Types Of Transformers
If the ratio of the number of turns in the secondary winding to that of the primary winding is greater than one, then the transformer is said to be a step-up transformer. In a step-up transformer, the voltage at the secondary winding is greater than the voltage applied at the primary winding.
However, if this ratio is less than one, the transformer is said to be a step-down...
Transformers with Off-Nominal Turns Ratios

