Related Experiment Video
Updated: Jun 14, 2025

A Test Bed to Examine Helmet Fit and Retention and Biomechanical Measures of Head and Neck Injury in Simulated Impact
Published on: September 21, 2017
Compliance with Headgear Evaluated by Force- and Temperature-Sensitive Monitoring Device: A Case-Control Study
Francesca Cremonini1, Ariyan Karami Shabankare1, Daniela Guiducci1
1Postgraduate School of Orthodontics, University of Ferrara, Via Luigi Borsari 46, 44121 Ferrara, Italy.
Abstract:
The aim was to objectively assess compliance in patients prescribed headgear and evaluate the impact of monitoring awareness, treatment duration, gender, and age on compliance levels. A total of 22 patients with Class II malocclusion wore the headgear integrated with the force and temperature sensitive Smartgear monitoring system (Smartgear, Swissorthodontics AG, Cham, Switzerland). Patients were instructed to wear the headgear for 13 h daily over a 3-month period. Randomly, 11 patients were informed that they monitored and 11 were not informed. Data were organized using Microsoft Excel and analyzed using R for statistical estimates, graphs, and hypothesis testing. Smartgear recorded an average daily compliance of 6.7 h. No statistically significant differences were found in cooperation between study group and control group over the 3 months of treatment, regardless of gender and age. However, there was slight greater cooperation in the first month than in the other months, and patients ≤10 years of age had almost 2 h more cooperation than their older counterparts. Moreover, the informed group exhibited an average of 1.1 more hours of cooperation per day than the uninformed group, which may carry clinical significance. This cooperation primarily occurred at night and was found to be statistically significant. Compliance among young patients typically remained lower than the prescribed level, regardless of their gender and psychological maturity. Although an awareness of monitoring does not seem to improve compliance, implementing such systems could still offer dentists a valuable means of obtaining objective information about their patients' adherence.
Related Concept Videos
Assessing Body Temperature - Temporal Artery
Step 1: Perform hand hygiene and don a fresh pair of gloves to prevent cross-infection and ensure patient safety.
Step 2: Explain the procedure to the patient to establish trust. Clear communication establishes trust with the patient, ensures they understand what to expect, promotes cooperation, and enhances comfort during the procedure.
Step 3: Assess the patient's...
Assessing Body Temperature - Tympanic membrane
Step 1: Begin by practicing good hand hygiene to prevent the transmission of microorganisms.
Step 2: Turn on the thermometer and wait until the ready sign appears on the screen to ensure accurate measurement.
Step 3: Slide the probe cover in place to prevent cross-contamination.
Step 4: Instruct the patient to tilt their head to the side for comfort and check for cerumen...

