Related Experiment Video
Updated: Jun 14, 2025

12:28
Quantification of Vascular Parameters in Whole Mount Retinas of Mice with Non-Proliferative and Proliferative Retinopathies
Published on: March 12, 2022
3.5K
Novel Method to Measure Volumes of Retinal Specific Entities.
Myrta Lippera1, Mariantonia Ferrara2,3,4, Karina Spiess1
1Manchester Royal Eye Hospital, Manchester University Hospitals NHS Foundation Trust, Manchester M13 9WL, UK.
Journal of Clinical Medicine
|August 29, 2024
Summary
A new optical-coherence-tomography (OCT) method simplifies volume calculation for retinal pathologies. This validated technique shows high agreement between observers and OCT software, improving volumetric analysis.
Area of Science:
- Ophthalmology
- Medical Imaging
- Biomedical Engineering
Background:
- Current optical-coherence-tomography (OCT) software has limitations in automating volumetric analysis for specific retinal pathologies.
- Accurate volumetric measurements are crucial for understanding and managing various retinal conditions.
Purpose of the Study:
- To describe and validate a novel, user-friendly OCT-based method for calculating specific volumes in retinal pathologies.
- To address the limitations of existing OCT software in automated volumetric analysis.
Main Methods:
- A manual drawing and area measurement approach was used on linear OCT scans.
- A formula (Volume = ∑area × OCT-scan distance) was applied for volumetric calculation.
- Measurements were performed by two independent observers and compared with automated OCT software, with re-acquisition after six weeks.
Main Results:
- The study included 62 eyes (30 normal foveal profile, 32 lamellar macular holes).
- Bland-Altman analysis demonstrated high inter- and intra-observer agreement for the proposed method.
- A high degree of agreement was found between manual measurements and automated OCT software in normal eyes.
Conclusions:
- The described OCT-based method is easy, reliable, and widely applicable for volumetric analysis of retinal pathologies.
- The method exhibits excellent inter- and intra-observer agreement.
- This technique can be utilized for studying any specific entity within retinal pathologies requiring volumetric assessment.