Accuracy Validation of the New Barrett True Axial Length Formula and the Optimized Lens Factor Using Sum-of-Segment
Sumitaka Miyamoto1, Kazutaka Kamiya2
1Aira Miyamoto Eye Clinic, Kagoshima 899-5213, Japan.
Abstract:
Objectives: This study aims to verify the accuracy of a new calculation formula, Barrett true axial length formula (T-AL), and the optimized lens factor (LF) for predicting postoperative refraction after cataract surgery. Methods: We included 156 Japanese patients who underwent cataract surgery using Clareon monofocal intraocular lenses at our clinic between January 2022 and June 2023. Postoperative spherical equivalent was calculated using subjective refraction values obtained 1 month post-surgery. The LFs were optimized so that the mean prediction error (PE) of each calculation formula was zero (zero optimization). We calculated the mean absolute PE (MAE) to assess accuracy and used a Friedman test for statistical comparisons. The accuracy of T-AL and the optimized LFs was compared with that of the conventional Barrett Universal II formula for ARGOS (AR-B) and OA-2000 (OA-B) with equivalent refractive index. Results: For T-AL, AR-B, and OA-B, the MAEs ± standard deviations were 0.225 ± 0.179, 0.219 ± 0.168, and 0.242 ± 0.206 D, respectively. The Friedman test showed no statistically significant differences among the three groups. The device-optimized LFs were 2.248-2.289 (T-AL), 2.236-2.246 (AR-B), and 2.07-2.08 (OA-B); the corresponding zero-optimized LFs were 2.262-2.287 (T-AL), 2.287-2.303 (AR-B), and 2.160-2.170 (OA-B). Conclusion: There were no significant differences in prediction accuracy among the formulas. However, the accuracy of LF optimization varied by device, with T-AL being closest to the value under zero optimization. This suggests that T-AL is clinically useful for predicting an accurate postoperative refraction without zero optimization.
More Related Videos
05:46Author Spotlight: Advancements in Refractive Surgical Correction for Presbyopia and Exploring Postoperative Visual Acuity
Published on: September 20, 2024
05:56Scleral Cross-linking Using Riboflavin and Ultraviolet-A Radiation for Prevention of Axial Myopia in a Rabbit Model
Published on: April 3, 2016
Related Concept Videos
Accuracy, limits, and approximation
Accuracy is defined as the closeness of the measured value to the true or actual value. In engineering mechanics, repeated measurements are taken during theoretical or experimental analyses to ensure that the result is precise and accurate.
The accuracy of any solution is based on the...
Adjusting a Traverse
Focusing of Light in the Eye
Relation between Poisson's ratio, Modulus of Elasticity and Modulus of Rigidity
Beams with Unsymmetric Loadings
The first moment-area theorem determines the slope at any point on the beam. This theorem indicates that the change in slope between two points on a beam...