Related Experiment Video
Updated: Jun 14, 2025

Potentiodynamic Corrosion Testing
Published on: September 4, 2016
Electrochemical Noise Analysis: An Approach to the Effectivity of Each Method in Different Materials
Jesús Manuel Jáquez-Muñoz1, Citlalli Gaona-Tiburcio2, Ce Tochtli Méndez-Ramírez3
1Universidad Autónoma de Ciudad Juárez, Ciudad Juárez 32315, Mexico.
Abstract:
Corrosion deterioration of materials is a major problem affecting economic, safety, and logistical issues, especially in the aeronautical sector. Detecting the correct corrosion type in metal alloys is very important to know how to mitigate the corrosion problem. Electrochemical noise (EN) is a corrosion technique used to characterize the behavior of different alloys and determine the type of corrosion in a system. The objective of this research is to characterize by EN technique different aeronautical alloys (Al, Ti, steels, and superalloys) using different analysis methods such as time domain (visual analysis, statistical), frequency domain (power spectral density (PSD)), and frequency-time domain (wavelet decomposition, Hilbert Huang analysis, and recurrence plots (RP)) related to the corrosion process. Optical microscopy (OM) is used to observe the surface of the tested samples. The alloys were exposed to 3.5 wt.% NaCl and H2SO4 solutions at room temperature. The results indicate that HHT and recurrence plots are the best options for determining the corrosion type compared with the other methods due to their ability to analyze dynamic and chaotic systems, such as corrosion. Corrosion processes such as passivation and localized corrosion can be differentiated when analyzed using HHT and RP methods when a passive system presents values of determinism between 0.5 and 0.8. Also, to differentiate the passive system from the localized system, it is necessary to see the recurrence plot due to the similarity of the determinism value. Noise impedance (Zn) is one of the best options for determining the corrosion kinetics of one system, showing that Ti CP2 and Ti-6Al-4V presented 742,824 and 939,575 Ω·cm2, while Rn presented 271,851 and 325,751 Ω·cm2, being the highest when exposed to H2SO4.
More Related Videos
Related Concept Videos
Electrogravimetric Analysis: Overview
To test the completeness of the...
Interfacial Electrochemical Methods: Overview
Electrochemistry: Overview
Electrodes: Overview
There are two main types of electrodes in electrochemical cells. The first type, known as the working or indicator electrode, has a potential that is sensitive to the analyte's concentration and reacts to changes in...
Controlled-Potential Coulometry: Electrolytic Methods
The chosen potential...
Electrodeposition
Electrodeposition can...

