Related Experiment Video
Updated: Jun 14, 2025

Determination of the Mechanical Properties of Flexible Connectors for Use in Insulated Concrete Wall Panels
Published on: October 19, 2022
Computational Research of the Efficiency of Using a Three-Layer Panel Made of Highly Porous Polystyrene Concrete
Galiya Rakhimova1, Nurlan Zhangabay2, Tatyana Samoilova1
1Department of Construction Materials and Technologies, Abylkas Saginov Karaganda Technical University, Karaganda 100000, Kazakhstan.
Abstract:
This paper presents linking computational research of the multilayer structure of the cladding of a three-layer panel made of highly porous polystyrene concrete developed using a new technology in comparison with traditional ones. The calculation of the thermal efficiency of the exterior fence was carried out in three stages, where the thermal regime was calculated from the values of temperature fields in the ELCUT 6.6 system, and the humidity and air modes were determined by the analytical method in the Maple system. The territory of central Kazakhstan (Karaganda) was selected as the research region, where the research showed that equating the thickness by the values of the actual and required heat transfer resistances of traditional multilayer structures to the developed one, the thickness of traditional structures increases from 3.09% to 27.83%. Moisture accumulation relative to the developed one occurs in all the studied structures. Thus, if in some cases of traditional structures moisture is collected by 2.61% and 9.48% less, in others moisture is collected by 27.94% and 119% more. However, the value of evaporated moisture during the drying period showed that all the moisture will evaporate during the specified period. Thus, all the structures meet the conditions for the inadmissibility of moisture for the annual period and the period of moisture accumulation. Moreover, the values of the actual and required permeabilities to air satisfy the condition, which affected the values of the temperature fields taking into account air filtration; the developed structure showed a positive effect for this value, and in traditional structures, the value of τint decreased to 1.35 °C depending on the option. The analytical results of the thermal inertia values of the developed and traditional multilayer structures showed that the developed structure exceeds traditional ones by up to 30.04% depending on the option, which is positive in the cold period. It was also found that the market prices of all traditional structures exceed the developed one by 1.2-2.5 times, depending on the design, which also emphasizes the positive aspects of the new design. Thus, the findings of this research will positively complement the catalog of products of external multilayer cladding structures made of effective materials and can be used by research communities and design organizations in the design of residential buildings.
More Related Videos
11:07Preparation of Aligned Steel Fiber Reinforced Cementitious Composite and Its Flexural Behavior
Published on: June 27, 2018
07:15A Testing Platform for Durability Studies of Polymers and Fiber-reinforced Polymer Composites under Concurrent Hygrothermo-mechanical Stimuli
Published on: December 11, 2014
Related Concept Videos
Design Example: Sustainability in Concrete Building
There are multiple approaches to achieve sustainability in a commercial concrete building. For instance, construct a concrete parking area under the building, utilizing pervious concrete paver blocks in open areas to facilitate rainwater collection through an underground...
Fiber Reinforced Concrete
Pore Size Distribution
Adequate...
Shrinkage in Concrete
When concrete is still in its plastic state, it can undergo a decrease in volume by about 1% of its absolute volume. This decrease is known as plastic shrinkage. It arises either...
Abrasion Resistance of Concrete
One such test is the revolving disc test, where three plates...
Porosity in Cement Paste
The balance of water to cement in the mix is...