Predictive value of isolated very low QRS voltage in tilt-table test for neurally mediated syncope
Haichao Chen1, Yiwei Cao2, Lei Liang1,3
1Department of Cardiology, Shaanxi Provincial People's Hospital, Xi'an, China.
Objective:
The cause of syncope is generally determined based on clinical manifestations. There has been little discussion about the value of electrocardiograms for diagnosing neurally mediated syncope. The aim of this study was to test the predictive value of the isolated very low QRS voltage in tilt-table testing for suspected neurally mediated syncope in a Chinese population.
Methods:
This retrospective study enrolled patients with suspected neurally mediated syncope. Tilt-table testing was a part of the diagnostic examination. Each patient underwent echocardiography and electrocardiogram. isolated very low QRS voltage referred to a voltage of ⩽0.3 mV for the QRS complex in an isolated frontal lead or ⩽0.7 mV for the QRS complex in an isolated precordial lead.
Results:
In total, 157 patients were included in the tilt-table testing positive group, and 242 patients were included in the tilt-table testing negative group. Compared with the testing negative group, the testing positive group had more patients with isolated very low QRS voltage in the frontal leads (p < 0.001). Moreover, for patients with isolated very low QRS voltage in the precordial leads, no significant difference was noted between the testing positive group and testing negative group (p = 0.289). Isolated very low QRS voltage in the frontal leads demonstrated 84.08% sensitivity and 74.38% specificity for a positive tilt-table testing response. The area under the curve of isolated very low QRS voltage for a positive tilt-table testing response in frontal leads was 0.806 (p < 0.0001).
Conclusion:
In patients with suspected neurally mediated syncope, isolated very low QRS voltage in the frontal leads is a parameter that can predict a positive tilt-table testing response. The presence of isolated very low QRS voltage in frontal leads can serve as a parameter for evaluating syncope patients.
Related Concept Videos
Electrocardiogram
Three major waveforms are present in a typical ECG recording: the P wave, the QRS complex, and...
Exercise Stress Test
Exercise stress testing, commonly known as a treadmill test, is a noninvasive procedure used to evaluate cardiovascular function and diagnose heart conditions.
Definition
An exercise stress test measures the heart's response to exertion using a treadmill or stationary bicycle. Chest electrodes record the heart's electrical activity through an ECG, and blood pressure is monitored regularly.
Purposes