A clinically operational method for three-dimensional dose calculations.

M D Altschuler, M R Sontag, P Bloch

    Physics in Medicine and Biology
    |March 1, 1985
    PubMed
    Summary
    This summary is machine-generated.

    Related Concept Videos

    You might also read

    Related Articles

    Articles linked to this work by shared authors, journal, and citation graph.

    Sort by
    Same author

    Search for a Narrow Resonance Lighter than 200 GeV Decaying to a Pair of Muons in Proton-Proton Collisions at sqrt[s]=13  TeV.

    Physical review letters·2020
    Same author

    Search for direct pair production of supersymmetric partners to the <math></math> lepton in proton-proton collisions at <math> </math>.

    The European physical journal. C, Particles and fields·2020
    Same author

    A multi-dimensional search for new heavy resonances decaying to boosted <math></math> <math></math> , <math></math> <math></math> , or <math></math> <math></math> boson pairs in the dijet final state at 13  <math></math>.

    The European physical journal. C, Particles and fields·2020
    Same author

    Search for production of four top quarks in final states with same-sign or multiple leptons in proton-proton collisions at <math> </math> <math></math>.

    The European physical journal. C, Particles and fields·2020
    Same author

    Search for Supersymmetry with a Compressed Mass Spectrum in Events with a Soft τ Lepton, a Highly Energetic Jet, and Large Missing Transverse Momentum in Proton-Proton Collisions at sqrt[s]=13  TeV.

    Physical review letters·2020
    Same author

    Measurement of electroweak production of a <math></math> boson in association with two jets in proton-proton collisions at <math> </math>.

    The European physical journal. C, Particles and fields·2020
    Same journal

    Effective contrast-enhanced preprocessing for intracranial artery segmentation in digital subtraction angiography.

    Physics in medicine and biology·2026
    Same journal

    Improving Plan Quality in Adaptive Proton Therapy Using an Interactive Dose Modification Tool.

    Physics in medicine and biology·2026
    Same journal

    Technical Note: Real-Time MLC Control and Latency Measurement Optimization with External Verification.

    Physics in medicine and biology·2026
    Same journal

    Fetus-Specific Hematopoietic Stem Cell Dosimetry Framework for Leukemia-Relevant Target Cells During Prenatal Development.

    Physics in medicine and biology·2026
    Same journal

    Deep learning-based dose prediction to enhance planning efficiency in cervical brachytherapy with hybrid applicators.

    Physics in medicine and biology·2026
    Same journal

    Corrigendum: Referenceless MR thermometry-a comparison of five methods (2017<i>Phys. Med. Biol</i>.<b>62</b>1-16).

    Physics in medicine and biology·2026
    See all related articles

    This study introduces a 3D dose calculation method for photon and neutron therapy using a scatter-air ratio-tissue-air ratio (SAR-TAR) model. It accurately calculates radiation doses for complex patient geometries, improving treatment planning.

    Area of Science:

    • Medical Physics
    • Radiation Oncology
    • Computational Biology

    Background:

    • Accurate three-dimensional (3D) radiation dose calculations are crucial for effective cancer therapy.
    • Traditional methods often struggle with complex beam geometries and patient anatomies.
    • Minicomputer-based calculations were previously limited in speed and scope.

    Purpose of the Study:

    • To present a novel 3D dose calculation method for photon and neutron beam therapy.
    • To enable accurate dose distribution assessment in complex patient geometries.
    • To compare the efficacy of the new 3D method against 2D techniques.

    Main Methods:

    • Implementation of a scatter-air ratio-tissue-air ratio (SAR-TAR) model for 3D dose computation.
    • Utilizing Clarkson integration for scatter dose determination, accounting for beam obliquity.

    Related Experiment Videos

  • Employing a 0.33 cm sampling grid on CT slices for dose calculation and display.
  • Generation of dose-volume histograms for patient, organs, and target volumes.
  • Main Results:

    • The SAR-TAR model allows for reasonable computation times on a minicomputer.
    • The method accurately determines radiation depth in patients with oblique beam incidence.
    • Dose-volume histograms provide comprehensive data for treatment evaluation.
    • Clinical efficacy demonstrated through comparison with 2D methods.

    Conclusions:

    • The developed 3D dose calculation method is clinically effective for photon and neutron therapy planning.
    • This approach offers improved accuracy and comprehensive dose assessment compared to 2D methods.
    • The SAR-TAR model provides a viable solution for advanced radiation therapy planning.