Related Experiment Video
Updated: Jun 14, 2025

The use of Biofeedback in Clinical Virtual Reality: The INTREPID Project
Published on: November 12, 2009
Comfort evaluation and physiological effects/autonomic nervous system response of inflatable deep pressure vest in
Mohamad Izzur Maula1,2,3, Muhammad Imam Ammarullah1,2,4, Hanifa Nur Fadhila2,5
1Department of Mechanical Engineering, Faculty of Engineering, Universitas Diponegoro, Semarang, 50275, Central Java, Indonesia.
Background:
Deep pressure therapy treats anxiety by triggering physiological responses and promoting calmness. Moreover, measuring user comfort can improve product quality.
Objective:
To investigate the physiological effects and subjective comfort level of inflatable deep pressure vests to enhance their calming effect.
Methods:
Experimental research was conducted with a one-group pretest-posttest design for physiological effects using pulse oximetry for peripheral pulse rate and a one-shot case study for three subscale parameters that help evaluate comfort (pressure, touch, and mobility) using the Numerical Rating Scale (NRS). Deep pressure intervention using the Inflatable Vest was performed for three sessions, each lasting 5 min.
Results:
This study was conducted with 46 participants (24 males, 22 females) aged 17-20 (19.52 ± 0.78). Although pulse rate consistently decreased in all sessions, session 1 showed a significant decrease (p = 0.014*, d = 0.379), whereas sessions 2 (p = 0.274, d = 0.163) and 3 (p = 0.597, d = 0.078) demonstrated non-significant decreases with small effect sizes. The pressure comfort subscale showed that 87.0 %, 4.3 %, and 8.7 % of the participants, and the touch comfort subscale test revealed that 82.6 %, 8.7 %, and 73.9 % of the participants rated it as comfortable, very comfortable, and less comfortable, respectively. The mobility subscale test showed that 73.9 % of the participants rated no limitation, 17.4 % rated somewhat limited, and only 8.7 % rated limitation. Decreased pulse rate and pressure comfort were significantly positively correlated (r = 0.282**, p < 0.01), whereas touch pressure and mobility were not (r = 0.160, p > 0.05; and r = 0.121, p > 0.05, respectively). Decreased pulse rate was also positively correlated with the overall score for the three aspects (r = 0.201*, p < 0.05).
Conclusions:
A comfortable inflatable deep pressure vest provides a physiologically calming effect for therapeutic modalities.
Related Concept Videos
Disorders of the Autonomic Nervous System
Raynaud's disease, also known as Raynaud's...
Assessment of the Cardiovascular System III: Palpation
Jugular Venous Pressure (JVP) Measurement
Position the patient at a thirty- to forty-five-degree angle or in a semi-fowler's position. Look for the highest point of pulsation in the internal jugular vein and measure the vertical distance to the angle of Loius or sternal angle. A normal JVP is 3-4 cm above...
Pre-Procedural Guidelines for Assessing Blood Pressure
Assessment of blood pressure in brachial artery(two-step method)
Exercise Stress Test
Exercise stress testing, commonly known as a treadmill test, is a noninvasive procedure used to evaluate cardiovascular function and diagnose heart conditions.
Definition
An exercise stress test measures the heart's response to exertion using a treadmill or stationary bicycle. Chest electrodes record the heart's electrical activity through an ECG, and blood pressure is monitored regularly.
Purposes
Autoregulation of Blood Flow
Chemical Signaling in Autoregulation
Chemical signaling operates at the precapillary sphincter level, inciting either contraction or relaxation....

