Low dose optimization for total-body 2-[18F]FDG PET/CT imaging: a single-center study on feasibility based on body
Taoying Gu1,2,3,4, Siwei Liu1,2,3,4, Xiaoguang Hou1,2,3,4
1Department of Nuclear Medicine, Zhongshan Hospital, Fudan University, 180 Fenglin Road, 200032, Shanghai, People's Republic of China.
Objectives:
Implementing personalization protocol in clinical routine necessitates diverse low-dose PET/CT scan protocols. This study explores the clinical feasibility of one-third (1/3) dose regimen and evaluates the diagnostic image quality and lesion detectability of BMI-based 1/3-injection doses for 2-[18F]FDG PET/CT imaging.
Methods:
Seventy-four cancer patients underwent total-body 2-[18F]FDG PET/CT examination, with 37 retrospectively enrolled as full-dose group (3.7 MBq/kg) and 37 prospectively enrolled as the 1/3-dose group (1.23 MBq/kg). The 1/3-dose group was stratified by BMI, with an acquisition time of 5 min (G5), 6 min (G6), and 8 min (G8) for BMI < 25, 25 ≤ BMI ≤ 29, and BMI > 29, respectively. Image quality was subjectively and objectively assessed, and lesion detectability was quantitatively analyzed.
Results:
Subjective assessments of 1/3-dose and full-dose PET images showed strong agreement among readers (κ > 0.88). In the 1/3-dose group, the Likert scores were above 4. G5, G6, and G8 showed comparable image quality, with G5 demonstrating higher lesion conspicuity than G6 and G8 (p = 0.045). Objective evaluation showed no significant differences in SUVmax, liver SUVmean and TBR between 1/3- and full-dose groups (p > 0.05). No statistical differences were observed in the SUVmax of primary tumor, SUVmean of liver and TBR across all BMI categories between the 1/3-dose and full-dose groups. Lesion detection rates showed no significant difference between the 1/3-dose (93.24%, 193/207) and full-dose groups (94.73%, 198/209) (p = 0.520).
Conclusion:
A BMI-stratified 1/3-dose regimen is a feasible low-dose alternative with clinically acceptable lesion detectability equivalent to full-dose protocol, potentially expanding the applicability of personalized protocols.
Clinical Relevance Statement:
This study demonstrated that BMI-stratified 1/3-dose regimens for [18F]FDG total-body PET/CT yielded equivalent outputs compared to the full-dose regimen, which aligns with clinical needs for personalization in dose and BMI.
Key Points:
Currently, limited personalized low-dose total-body PET/CT protocols are available, particularly for patients with varied BMI. Reducing the radiotracer dose to 1/3 the standard demonstrated comparable image quality and lesion detectability equivalent to full dose. BMI-stratified 1/3-dose regimen is a clinically feasible low-dose alternative.