Related Experiment Video
Updated: Jun 14, 2025

Author Spotlight: Assessing the Reliability of Doppler Ultrasound in Measuring Leg Blood Flow
Published on: December 15, 2023
Reliability of beat-to-beat blood pressure variability in older adults
Trevor Lohman1, Isabel J Sible2, Fatemah Shenasa3
1Leonard Davis School of Gerontology, University of Southern California, Los Angeles, CA, USA.
Abstract:
Blood pressure variability (BPV) is emerging as an important risk factor across numerous disease states, including cerebrovascular and neurodegenerative disease in older adults. However, there is no current consensus regarding specific use cases for the numerous available BPV metrics. There is also little published data supporting the ability to reliably measure BPV across metrics in older adults. The present study derived BPV metrics from continuous beat-to-beat blood pressure monitoring data. Two sequential 7 min waveforms were analyzed. Absolute and relative reliability testing was performed. Differences between antihypertensive medication users and non-users on BPV metric reliability was also assessed. All sequence and dispersion based BPV metrics displayed good test-retest reliability. A measure of BP instability displayed only moderate reliability. Systolic and diastolic average real variability displayed the highest levels of reliability at ICC = 0.87 and 0.82 respectively. Additionally, systolic average real variability was the most reliable metric in both the antihypertensive use group, and the no antihypertensive use group. In conclusion, beat-to-beat dispersion and sequence-based metrics of BPV can be reliably obtained in older adults using noninvasive continuous blood pressure monitoring. Average real variability may be the most reliable and specific beat-to-beat blood pressure variability metric due to its decreased susceptibility to outliers and low frequency blood pressure oscillations.
Related Concept Videos
Special considerations while measuring blood pressure
Monitoring Both Arms:
Monitoring BP in both arms during the initial assessment is advisable, as the systolic value may differ by five to ten mm Hg between arms. For subsequent BP assessments, use the arm with the higher reading.
Errors occurring during blood pressure monitoring
Several factors...
Measurement of Blood Pressure
Assessment of blood pressure in brachial artery(two-step method)
Pre-Procedural Guidelines for Assessing Blood Pressure
Assessment of blood pressure in brachial artery(one-step method)
Prepare for the Procedure:

