Related Experiment Video
Updated: Jun 14, 2025

Trabecular Meshwork Response to Pressure Elevation in the Living Human Eye
Published on: June 20, 2015
Relationship Between Asymmetry of Transverse Sinus and Difference in Intraocular Pressure
Dan Zhu1, Weiguang Zhang, Dong Qiu
1The Second Affiliated Hospital of Harbin Medical University, Harbin, China.
Background And Objective:
This study used two-dimensional time-of-flight magnetic resonance venography (2D TOF MRV) to show the shape of the transverse sinus and to determine whether there is a correlation between the asymmetry of the transverse sinus morphology and the intraocular pressure (IOP) of the two eyes.
Methods:
In this study, 63 male and 42 female volunteers were included. Those with obvious neurological diseases and eye diseases were excluded. According to the morphology of the transverse sinus scanned with 2D TOF MRV, subjects were divided into five groups. The IOP of the volunteers was measured separately.
Results:
The difference between group I and group V is statistically significant (Z = 6.78, P < 0.01). Statistically, significant differences also existed among the IOP of each group, including the mean values of both eyes and the difference between the right eye and the left eye. The asymmetry of the transverse sinus maintained a negative correlation with the right IOP (r = 0.51, P < 0.01) and the difference between the right eye and the left eye (r = 0.79, P < 0.01). The asymmetry and the left IOP had no statistical correlation.
Conclusion:
The preliminary conclusion of this study is that if one side of the transverse sinus is thicker, the drainage-related ocular veins are relatively coarser, and the IOP is relatively lower. The 2D TOF MRV examination can be used as an examination to show the shape of the transverse sinus. It is a display method to provide a feasible means of inspection for a reasonable interpretation.
Related Concept Videos
Glaucoma: Overview
Angle Closure Glaucoma: Treatment
Accessory Structures of the Eye
Graphical and Analytic Representation of Sinusoids
The first step is measuring the peak-to-peak value, which is twice the amplitude of the sinusoid. This provides information about the maximum voltage swing of the waveform.
Secondly, the period and angular frequency are determined. The period is the time taken for one complete cycle of the waveform, while...
Open Angle Glaucoma: Treatment
Drugs such as carbonic anhydrase inhibitors, α2- and...
Pressure Relationships in Thoracic Cavity
Breathing Mechanisms
Both intra-alveolar and intrapleural pressures rely on specific lung properties. The ability to breathe—allowing air to enter the lungs...

