Data-knowledge co-driven feature based prediction model via photoplethysmography for evaluating blood pressure
Qingfeng Tang1, Chao Tao2, Xin Li3
1Digital and Intelligent Health Research Center, Anqing Normal University, Anqing 246133, China; School of Traditional Chinese Medicine, Shanghai University of Traditional Chinese Medicine, Shanghai 201203, China.
Background:
Knowledge feature (KF) with clear physiological significance of photoplethysmography are widely used in predicting blood pressure. However, KF primarily focus on local information of photoplethysmography, which may struggle to capture the overall characteristics.
Methods:
Firstly, functional data analysis (FDA) was introduced to extract two types of data feature (DF). Furthermore, data-knowledge co-driven feature (DKCF) was proposed by combining FDA and constraints of KF. Finally, random forest, ada boost, gradient boosting, support vector machine and deep neural network were adopted, to compare the abilities of KF, DFs and DKCF in predicting blood pressure with two datasets (A published dataset and a self-collected dataset).
Results:
Under the premise of extracting only 9 features, the average mean absolute errors (MAE) of systolic blood pressure (SBP) and diastolic blood pressure (DBP) obtained by DKCF are both the smallest in dataset 1. In dataset 2, DKCF acquires the smallest MAE in predicting SBP and obtains the second smallest MAE in predicting DBP.
Conclusions:
The results demonstrate that low-dimensional DKCF of photoplethysmography is closely correlated with blood pressure, which may serve as an important indicator for health assessment.
Related Concept Videos
Pre-Procedural Guidelines for Assessing Blood Pressure
Equipments Used To Measure Blood Pressure
This invasive approach involves cannulating a peripheral artery. During each cardiac contraction, pressure generates mechanical motion within the catheter, transmitted through rigid, fluid-filled tubing to a transducer. This transducer converts mechanical motion into electrical signals displayed as waveforms on a monitor. An automatic flushing system prevents blood backflow. Due to the potential risk of unexpected arterial blood loss, this method is primarily used in intensive...
Assessment of blood pressure in brachial artery(two-step method)
Assessment of blood pressure in brachial artery(one-step method)
Prepare for the Procedure:
Special considerations while measuring blood pressure
Monitoring Both Arms:
Monitoring BP in both arms during the initial assessment is advisable, as the systolic value may differ by five to ten mm Hg between arms. For subsequent BP assessments, use the arm with the higher reading.
Measurement of Blood Pressure