Related Experiment Video
Updated: Jul 28, 2026

Radiation Planning Assistant - A Streamlined, Fully Automated Radiotherapy Treatment Planning System
Published on: April 11, 2018
Optimizing volumetric modulated arc therapy prostate planning using an automated Fine-Tuning process through dynamic
Hasan Cavus1,2,3, Thierry Rondagh1,2, Alexandra Jankelevitch1,2
1Department of Radiation Oncology, Jessa Hospital, 3500 Hasselt, Belgium.
Abstract:
In radiotherapy treatment planning, optimization is essential for achieving the most favorable plan by adjusting optimization criteria. This study introduced an innovative approach to automatically fine-tune optimization parameters for volumetric modulated arc therapy prostate planning, ensuring all constraints were met. A knowledge-based planning model was invoked, and the fine-tuning process was applied through an in-house developed script. Among 25 prostate plans, this fine-tuning increased the number of plans meeting all constraints from 10/25 to 22/25, with a reduction in mean monitor units per gray without increasing plan's complexity. This automation improved efficiency by saving time and resources in treatment planning.