Lessons learned: drive-through COVID-19 clinic testing during an adaptive epidemic response and a point-of-care test
Leah Rankine-Wilson1,2, Teresa Oncken3, Irshan Basrewan1
1Department of Clinical Microbiology, PathWest Laboratory Medicine WA, Fiona Stanley Hospital, Murdoch, Australia.
Abstract:
Background. The COVID-19 pandemic demonstrated a need for robust SARS-CoV-2 test evaluation infrastructure to underpin biosecurity and protect the population during a pandemic health emergency.Gap statement. The first generation of rapid antigen tests was less accurate than molecular methods due to their inherent sensitivity and specificity shortfalls, compounded by the consequences of self-testing. This created a need for more accurate point-of-care SARS-CoV-2 detection methods.Aim. Here we present the lessons-learned during the COVID-19 emergency response in Western Australia including the detailed set-up, evaluation and operation of rapid antigen test in a state-run drive-through sample collection service during the COVID-19 pandemic after the strict border shutdown ended.Methods. We report a conformity assessment of a novel, second-generation rapid antigen test (Virulizer) comprising a technician-operated rapid lateral flow immunoassay with fluorescence-based detection.Results. The Virulizer rapid antigen test demonstrated up to 100% sensitivity (95% CI: 61.0-100%), 91.94% specificity (95% CI: 82.5-96.5%) and 92.65% accuracy when compared to a commercial PCR assay method. Wide confidence intervals in our series reflect the limits of small sample size. Nevertheless, the Virulizer assay performance was well-suited to point-of-care screening for SARS-CoV-2 in a drive-through clinic setting.Conclusion. The adaptive evaluation process necessary under changing pandemic conditions enabled assessment of a simple sample collection and point-of-care testing process, and showed how this system could be rapidly deployed for SARS-CoV-2 testing, including to regional and remote settings.
More Related Videos
10:10Development of a Lateral Flow Immunochromatographic Strip for Rapid and Quantitative Detection of Small Molecule Compounds
Published on: November 13, 2021
07:13Author Spotlight: High-Quality Quantum Dot Nanobeads for Sensitive Fluorescent Lateral Flow Immunoassays
Published on: June 28, 2024
Related Concept Videos
Pneumonia III: Complications and Assessment
Sensitivity, Specificity, and Predicted Value
Sensitivity is the...
Automated Microbial Diagnostics