Related Experiment Video
Updated: Jun 14, 2025

08:17
Murine Echocardiography of Left Atrium, Aorta, and Pulmonary Artery
Published on: February 20, 2017
14.3K
The preferable position for quantifying left ventricular diameter by transthoracic echocardiography.
Takafumi Nakayama1,2, Yasuhiro Shintani3, Masashi Yokoi3
1Department of Cardiology, Nagoya City University West Medical Center, 1-1-1, Hirate-cho, Kita-ku, Nagoya, Aichi, 462-8508, Japan. tnakayama83@gmail.com.
Journal of Echocardiography
|September 2, 2024
Summary
Measuring left ventricular (LV) diameter at the LV mid-level provides a more accurate representation of LV volume compared to the mitral valve tip level. LV mid-level measurements are also not influenced by other factors, ensuring reliable results.
Area of Science:
- Cardiology
- Medical Imaging
- Echocardiography
Background:
- Accurate quantification of left ventricular (LV) diameter is crucial for assessing cardiac function.
- The optimal measurement site (mitral valve tip level vs. LV mid-level) for echocardiographic LV diameter remains unclear.
- Factors influencing measurement error in echocardiographic LV diameter assessment require elucidation.
Purpose of the Study:
- To compare the accuracy of LV diameter measurements at the mitral valve tip level (MV-tip) versus the LV mid-level (LV-mid).
- To identify factors that affect measurement errors in echocardiographic LV diameter assessments.
Main Methods:
- 150 patients without myocardial infarction or local asynergy underwent echocardiography and cardiac magnetic resonance imaging (CMRI).
- Echocardiographic LV diastolic diameter (LVDD) and LV systolic diameter (LVDS) were measured at both MV-tip and LV-mid.
- LV end-diastolic volume (LVEDV) and LV end-systolic volume (LVESV) were quantified by CMRI.
Main Results:
- LV diameter measurements were smaller at MV-tip than at LV-mid.
- LV-mid measurements showed stronger correlations with CMRI-derived LV volumes (LVDD-LVEDV: R=0.89; LVDS-LVESV: R=0.93) compared to MV-tip measurements (LVDD-LVEDV: R=0.82; LVDS-LVESV: R=0.87).
- Aortic wedging angle, Valsalva diameter, left atrial diameter, patient height, and LV mass influenced measurement error, except for LVDD at the LV-mid level.
Conclusions:
- Echocardiographic LV diameter measured at the LV-mid level correlates better with LV chamber volumes determined by CMRI.
- LV diameter measurements at the LV-mid level are not affected by other confounding factors, suggesting superior reliability.

