Related Experiment Video
Updated: Jun 14, 2025

Author Spotlight: Integrating Ultrasound Imaging with Biochemical Markers for Thyroid Disease Diagnosis
Published on: February 9, 2024
Comparison of Thyroid Uptake Values Measured from 131I Scintigraphy and Uptake Probe in Hyperthyroid Patients
Nami Yeyin1,2,3, Sinem Akyol1,2, Lebriz Uslu-Beşli1,2
1Cerrahpasa Medical Faculty, Istanbul University-Cerrahpasa, Istanbul, Turkey.
Objective:
Thyroid uptake test plays an important role in diagnosis, treatment planning and radioiodine dose determination in patients with hyperthyroidism. The aim of this study was to compare the % uptake values calculated with gamma camera and uptake probe after diagnostic 131I application in hyperthyroid patients.
Materials And Methods:
In this study, % uptake values were measured using a thyroid uptake probe and gamma camera in 32 patients who underwent thyroid radioiodine uptake measurement in our Nuclear Medicine center. Thyroid uptake measurements were prepared in the neck phantom with 0.74-0.925 MBq activity of 131I radionuclide. After counting the phantom with 131I separately in the uptake probe and gamma camera, 131I sample was orally administered to the patient. % uptake values were calculated by the uptake probe measurements and drawing regions of interest (ROI) from scintigraphic images at 2 and 24 h.
Results:
The 2-h mean % uptake values in the probe and gamma camera were calculated as 30.5 ± 20.4 and 27.1 ± 18.6, respectively. The 24-h mean % uptake values in the thyroid probe and gamma camera were calculated as 57.6 ± 21.9 and 55.3 ± 21.5, respectively. Linear regression analyses for the 2- and 24-h % uptake values calculated with the probe and gamma camera were found as R2 = 0.8412 and R2 = 0.7313, respectively.
Conclusion:
The 2- and 24-h % uptake values with the probe and gamma camera were found to be consistent with each other, indicating that they can be safely used interchangeably in patients with hyperthyroidism.
Objective:
Thyroid uptake test plays an important role in diagnosis, treatment planning and radioiodine dose determination in patients with hyperthyroidism. The aim of this study was to compare the % uptake values calculated with gamma camera and uptake probe after diagnostic 131I application in hyperthyroid patients.
Materials And Methods:
In this study, % uptake values were measured using a thyroid uptake probe and gamma camera in 32 patients who underwent thyroid radioiodine uptake measurement in our Nuclear Medicine center. Thyroid uptake measurements were prepared in the neck phantom with 0.74-0.925 MBq activity of 131I radionuclide. After counting the phantom with 131I separately in the uptake probe and gamma camera, 131I sample was orally administered to the patient. % uptake values were calculated by the uptake probe measurements and drawing regions of interest (ROI) from scintigraphic images at 2 and 24 h.
Results:
The 2-h mean % uptake values in the probe and gamma camera were calculated as 30.5 ± 20.4 and 27.1 ± 18.6, respectively. The 24-h mean % uptake values in the thyroid probe and gamma camera were calculated as 57.6 ± 21.9 and 55.3 ± 21.5, respectively. Linear regression analyses for the 2- and 24-h % uptake values calculated with the probe and gamma camera were found as R2 = 0.8412 and R2 = 0.7313, respectively.
Conclusion:
The 2- and 24-h % uptake values with the probe and gamma camera were found to be consistent with each other, indicating that they can be safely used interchangeably in patients with hyperthyroidism.
More Related Videos
09:49A Whole Body Dosimetry Protocol for Peptide-Receptor Radionuclide Therapy PRRT: 2D Planar Image and Hybrid 2D+3D SPECT/CT Image Methods
Published on: April 24, 2020
10:04Radionuclide-fluorescence Reporter Gene Imaging to Track Tumor Progression in Rodent Tumor Models
Published on: March 13, 2018
Related Concept Videos
Imaging Studies II: Positron Emission Tomography and Scintigraphy
Fundamental Principles of PET
Synthesis and Regulation of Thyroid Hormones
Upon reaching the thyroid gland, TSH stimulates the follicular cells' active uptake of iodide ions from the blood. The ions diffuse to the apical surface of the cells and are oxidized to iodine. The...
Positron Emission Tomography
One of the main requirements of a PET scan is a positron-emitting radioisotope, which is produced in a cyclotron and then attached to a substance used by the part of the body...
Radiological Investigation III: Pulmonary Angiogram and PET Scan
Pulmonary Angiogram
A Pulmonary Angiogram is an invasive procedure involving injecting a contrast medium through a catheter threaded into the pulmonary artery or the right side of the heart to visualize the pulmonary vasculature. Computed Tomography (CT) scans have mainly replaced this...