Radiation Planning Assistant - A Streamlined, Fully Automated Radiotherapy Treatment Planning System
Published on: April 11, 2018
Fully automated radiotherapy treatment planning: A scan to plan challenge
Mark J Gooding1, Shafak Aluwini2, Teresa Guerrero Urbano3
1Inpictura Ltd, 5 The Chambers, Vineyard, Abingdon OX14 3PX, United Kingdom; Division of Cancer Sciences, Faculty of Biology, Medicine and Health, The University of Manchester, M20 4BX Manchester, United Kingdom.
Background And Purpose:
Over the past decade, tools for automation of various sub-tasks in radiotherapy planning have been introduced, such as auto-contouring and auto-planning. The purpose of this study was to benchmark what degree of automation is possible.
Materials And Methods:
A challenge to perform automated treatment planning for prostate and prostate bed radiotherapy was set up. Participants were provided with simulation CTs and a treatment prescription and were asked to use automated tools to produce a deliverable radiotherapy treatment plan with as little human intervention as possible. Plans were scored for their adherence to the protocol when assessed using consensus expert contours.
Results:
Thirteen entries were received. The top submission adhered to 81.8% of the minimum objectives across all cases using the consensus contour, meeting all objectives in one of the ten cases. The same system met 89.5% of objectives when assessed with their own auto-contours, meeting all objectives in four of the ten cases. The majority of systems used in the challenge had regulatory clearance (Auto-contouring: 82.5%, Auto-planning: 77%). Despite the 'hard' rule that participants should not check or edit contours or plans, 69% reported looking at their results before submission.
Conclusions:
Automation of the full planning workflow from simulation CT to deliverable treatment plan is possible for prostate and prostate bed radiotherapy. While many generated plans were found to require none or minor adjustment to be regarded as clinically acceptable, the result indicated there is still a lack of trust in such systems preventing full automation.