Related Experiment Video
Updated: Jun 14, 2025

Diffuse Optical Spectroscopy for the Quantitative Assessment of Acute Ionizing Radiation Induced Skin Toxicity Using a Mouse Model
Published on: May 27, 2016
Exposure-Response-Based Multiattribute Clinical Utility Score Framework to Facilitate Optimal Dose Selection for
Yiming Cheng1, Shuyu Chu2, Jie Pu1
1Clinical Pharmacology, Pharmacometrics & Bioanalysis, Bristol Myers Squibb, Princeton, NJ.
Purpose:
The advent of new therapeutic modalities highlighted deficiencies in the traditional maximum tolerated dose approach for oncology drug dose selection and prompted the Food and Drug Administration (FDA)'s Project Optimus initiative, which suggests that sponsors take a holistic approach, including efficacy, safety, and pharmacokinetic (PK) and pharmacodynamic data, in conjunction with integrated exposure-response (ER) analyses. However, this method comes with an inherent challenge of the collation of the multisource data. To address this issue, an ER-based clinical utility score (CUS) framework, combining benefit and risk into a single measurement, was developed.
Methods:
Model-predicted outcomes for each clinically relevant end point, informed by ER modeling, are converted to a CUS using a user-defined utility function. Thereafter, individual CUS is integrated into a single score with user-defined weighting for each end point. The user-defined weighting feature allows the user to incorporate expert knowledge/understanding into weighing the product's benefit versus risk profile.
Results:
To validate the framework, data were leveraged from over 50 oncology programs from 2019 to 2023 on the basis of FDA new drug application/biologics license application review packages and/or related literature studies. Five representative cases were selected for in-depth evaluation. Results showed that the optimal benefit-risk ratio (highest CUS) was consistently observed at PK exposures synonymous with recommended doses. A recurring theme across cases was a greater emphasis on safety over efficacy in oncology drug dose determination.
Conclusion:
The ER-based CUS framework offers a strategic tool to navigate the complexities of dose selection in oncology programs. It serves as a pillar to the importance of integrative data analysis, aligning with the vision of Project Optimus, and demonstrates its potential in guiding dose optimization by balancing therapeutic benefits against risk.
More Related Videos
06:20Irradiator Commissioning and Dosimetry for Assessment of LQ α and β Parameters, Radiation Dosing Schema, and in vivo Dose Deposition
Published on: March 11, 2021
05:39Author Spotlight: Radiotherapy and Clonogenic Assays for Advancing Cancer Research and Personalized Medicine
Published on: April 5, 2024
Related Concept Videos
Dose-Response Relationship: Overview
Dose-Response Relationship: Potency and Efficacy
Dose-Response Relationship: Selectivity and Specificity
Types of Biopharmaceutical Studies: Controlled and Non-Controlled Approaches
Non-controlled studies, commonly employed for initial exploration, lack a control group, rendering them susceptible to biases and external influences. In contrast,...
Structure-Activity Relationships and Drug Design
SAR studies the intricate relationship between a drug's chemical structure and biological activity. It focuses on understanding how modifications to a drug's structure can influence...
Combination Therapies and Personalized Medicine
The combination of the drug acetazolamide and sulforaphane is a good example of combination therapy to treat cancer. The cells in the interior of a large tumor often die due to the hypoxic and...