Related Experiment Video
Updated: Jun 14, 2025

Computerized Adaptive Testing System of Functional Assessment of Stroke
Published on: January 7, 2019
Psychometric properties of computerized adaptive testing for chronic obstructive pulmonary disease patient-reported
Jiajia Wang1,2,3, Yang Xie1,2,3, Zhenzhen Feng1,2,3
1Collaborative Innovation Center for Chinese Medicine and Respiratory Diseases Co-constructed by Henan Province & Education Ministry of P.R. China, Henan University of Chinese Medicine, 156 Jinshui East Road, Zhengzhou, 450046, China.
Background:
Computerized adaptive testing (CAT) is an effective way to reduce time, repetitious redundancy, and respond burden, and has been used to measure outcomes in many diseases. This study aimed to develop and validate a comprehensive disease-specific CAT for chronic obstructive pulmonary disease (COPD) patient-reported outcome measurement.
Methods:
The discrimination and difficulty of the items from the modified patient-reported outcome scale for COPD (mCOPD-PRO) were analyzed using item response theory. Then the initial item, item selection method, ability estimation method, and stopping criteria were further set based on Concerto platform to form the CAT. Finally, the reliability and validity were validated.
Results:
The item discrimination ranged from 1.05 to 2.71, and the item difficulty ranged from - 3.08 to 3.65. The measurement reliability of the CAT ranged from 0.910 to 0.922 using random method, while that ranged from 0.910 to 0.924 using maximum Fisher information (MFI) method. The content validity was good. The correlation coefficient between theta of the CAT and COPD assessment test and modified Medical Research Council dyspnea scale scores using random method was 0.628 and 0.540 (P < 0.001; P < 0.001) respectively, while that using MFI method was 0.347 and 0.328 (P = 0.007; P = 0.010) respectively. About 11 items (reducing by 59.3%) on average were tested using random method, while about seven items (reducing by 74.1%) on average using MFI method. The correlation coefficient between theta of the CAT and mCOPD-PRO total scores using random method was 0.919 (P < 0.001), while that using MFI method was 0.760 (P < 0.001).
Conclusions:
The comprehensive disease-specific CAT for COPD patient-reported outcome measurement is well developed with good psychometric properties, which can provide an efficient, accurate, and user-friendly measurement for patient-reported outcome of COPD.
More Related Videos
06:28E-Patient Counseling Trial E-PACO: Computer Based Education versus Nurse Counseling for Patients to Prepare for Colonoscopy
Published on: August 1, 2019
08:44Author Spotlight: Integrating Alveolar-Capillary Reserve Measurements in Exercise Adaptation and Therapeutic Strategies
Published on: February 2, 2024
Related Concept Videos
Chronic Obstructive Pulmonary Disease-IV: Assessement and Diagnostic Studies
Medical History
Chronic Obstructive Pulmonary Disease-I: Introduction
COPD: Management Using Bronchodilators and Corticosteroids
Self-Report Tests of Personality
Pulmonary Function Tests
Pulmonary Function Tests are crucial diagnostic tools for assessing respiratory function, particularly in patients with chronic respiratory disorders. They comprehensively evaluate lung volumes, ventilatory function, breathing mechanics, diffusion, and gas exchange. These tests help diagnose pulmonary diseases and play a significant role in monitoring disease progression, evaluating disability, and assessing response to therapy.
PFTs involve using a spirometer, a...
Chronic Obstructive Pulmonary Disease
Smoking is a primary risk factor for COPD, with over 80% of patients having a history of it. Patients typically experience progressive dyspnea or labored breathing, frequent coughing, and recurrent pulmonary infections. Many eventually succumb to respiratory failure, characterized by...