Continuous Venous-Arterial Doppler Ultrasound During a Preload Challenge
Published on: January 20, 2023
Changes of intracardiac flow dynamics measured by HyperDoppler in patients with aortic stenosis
Jolanda Sabatino1,2,3,4, Isabella Leo1,3, Antonio Strangio1,3
1Department of Experimental and Clinical Medicine, Magna Graecia University, Catanzaro, Italy.
Aims:
Assessment of intracardiac flow dynamics has recently acquired significance due to the development of new measurement methods based on echocardiography. Recent studies have demonstrated that cardiac abnormalities are associated with changes in intracardiac vortical flows. Yet, no previous study assessed the impact of aortic stenosis (AS) on intracardiac vortices. This study aims to explore the clinical potential of additional information provided by quantifying intracardiac flow dynamics in patients with AS.
Methods And Results:
One hundred and twenty patients with severe AS, sixty patients with concentric ventricular remodelling (VR), and hundred controls (CTRL) were prospectively included and underwent non-invasive evaluation of intracardiac flow dynamics. In addition to standard echocardiography, fluid dynamics were assessed by means of HyperDoppler. Vortex depth (P < 0.001), vortex length (P = 0.003), vortex intensity (P < 0.001), and vortex area (P = 0.049) were significantly increased in AS compared with CTRL. In addition, mean energy dissipation was significantly higher in AS compared with CTRL (P < 0.001) and VR (P = 0.002). At receiver operating characteristic analysis, vortex depth showed the best discrimination capacity for AS (P < 0.001).
Conclusion:
Changes in fluid dynamics-based HyperDoppler indices can be reliably assessed in patients with AS. Significant changes in vortex depth and intensity can selectively differentiate AS from both concentric remodelling and healthy CTRLs, suggesting that the assessment of intracardiac flow dynamics may provide complementary information to standard echocardiography to better characterize patients' subsets.
More Related Videos
09:24O-Ring Aortic Banding Versus Traditional Transverse Aortic Constriction for Modeling Pressure Overload-Induced Cardiac Hypertrophy
Published on: October 6, 2022
06:39Ultrasound Based Assessment of Coronary Artery Flow and Coronary Flow Reserve Using the Pressure Overload Model in Mice
Published on: April 13, 2015
Related Concept Videos
Assessing Blood pressure using a doppler ultrasound
Pre-Procedural Guidelines for Doppler Ultrasound Blood Pressure Assessment:
Preparation of Equipment:
Equipments Used To Measure Blood Pressure
This invasive approach involves cannulating a peripheral artery. During each cardiac contraction, pressure generates mechanical motion within the catheter, transmitted through rigid, fluid-filled tubing to a transducer. This transducer converts mechanical motion into electrical signals displayed as waveforms on a monitor. An automatic flushing system prevents blood backflow. Due to the potential risk of unexpected arterial blood loss, this method is primarily used in intensive...