Correcting Peripherally Inserted Central Catheter Placement by External Manipulation of the Upper Limb Extremity
Varun Muddasani1, Akshatha P1, A Asha1
1Neonatology, Saveetha Medical College and Hospitals, Saveetha Institute of Medical and Technical Sciences, Chennai, IND.
Cureus
|September 5, 2024
Summary
Repositioning a peripherally inserted central catheter (PICC) in neonates is possible by adjusting arm position. This non-invasive technique can help achieve optimal central venous catheter placement in the neonatal intensive care unit (NICU).
Area of Science:
- Neonatal intensive care
- Vascular access devices
- Pediatric critical care
Background:
- Peripherally inserted central catheters (PICCs) are vital for administering medications and fluids in neonatal intensive care units (NICUs).
- Optimal placement of PICCs is crucial for effective treatment but can be challenging in neonates.
- Accurate catheter tip positioning is essential to prevent complications.
Observation:
- A case study involving a preterm infant in the NICU requiring a central venous catheter.
- Initial PICC insertion via the right basilic vein resulted in malpositioning into the right internal jugular vein.
- Imaging confirmed the catheter's incorrect placement.
Findings:
- External manipulation of the infant's right arm was used to adjust the catheter tip depth.
- Successful repositioning of the catheter tip into the superior vena cava (SVC) was achieved by altering arm position.
- This demonstrates the direct impact of extremity manipulation on PICC tip location.
Implications:
- Arm positioning is a critical factor influencing PICC placement accuracy in neonates.
- External extremity manipulation offers a simple, non-invasive method for adjusting PICC position.
- This technique provides a valuable alternative to more invasive procedures for correcting malpositioned catheters.