Related Experiment Video
Updated: Jun 14, 2025

Workflow Based on the Combination of Isotopic Tracer Experiments to Investigate Microbial Metabolism of Multiple Nutrient Sources
Published on: January 22, 2018
Coping with spectral interferences when measuring water stable isotopes of vegetables
Barbara Herbstritt1, Lena Wengeler1, Natalie Orlowski1,2
1Faculty of Environment and Natural Resources, University of Freiburg, Freiburg im Breisgau, Germany.
Rationale:
Laser-based analyzers are widely used in ecohydrology to analyze plant water isotopic compositions (δ18O and δ2H). The suitability of three different water extraction and isotope equilibration techniques was compared. We examined whether co-extracted volatile organic compounds (VOCs) affect laser-based isotope measurements and used the instrument's spectral parameters to post-correct for interfering VOCs.
Methods:
Cryogenic vacuum extraction, vapor headspace equilibration in bags, and vapor equilibration in situ probes were used to extract liquid water or water vapor for laser-based isotope analysis (cavity ring-down spectrometry, CRDS). Isotope data were calibrated by standards for each method separately. Spectral parameters of the instrument, appropriate to identify spectral interferences with MeOH and CH4, were identified and used for post-correction. Differences between the three methods and between the origins of the vegetables were identified by statistical tests.
Results:
VOCs were found in various amounts for the three different methods. They were co-extracted or co-equilibrated during the different extraction or equilibration methods. Correlation coefficients of isotope data and "CH4" (spectral parameter) were 0.99 or better; however, slopes for δ18O were similar on different instrument types but different for δ2H. Our correction approach improved results and inter-comparability of the methods considerably without knowing the chemical composition of the plant sap.
Conclusions:
All three methods were sensitive enough to distinguish and resolve differences in natural abundance. Data quality was improved by the "CH4 correction" approach but could probably be optimized by a plant species-specific correction. Standardized tools for contaminant removal or post-correction applications from manufacturers, in particular for vapor-mode analysis, are still needed.
More Related Videos
07:57Sampling and Pretreatment of Tooth Enamel Carbonate for Stable Carbon and Oxygen Isotope Analysis
Published on: August 15, 2018
10:16Design and Operation of a Continuous 13C and 15N Labeling Chamber for Uniform or Differential, Metabolic and Structural, Plant Isotope Labeling
Published on: January 16, 2014
Related Concept Videos
Atomic Absorption Spectroscopy: Interference
Spectral interference occurs when signals from other elements or molecules overlap with the analyte signal, falsely elevating or masking the analyte's absorbance. This interference can be corrected using Zeeman,...
Inductively Coupled Plasma-Mass Spectrometry (ICP-MS): Interferences
Atomic Emission Spectroscopy: Interference
¹³C NMR: ¹H–¹³C Decoupling
A broadband decoupling technique is used to simplify these complex, sometimes overlapping, signals. Broadband decoupling relies on a...