Related Experiment Video
Updated: Jun 14, 2025

Positron Emission Tomography Using 64-Copper as a Tracer for the Study of Copper-Related Disorders
Published on: April 28, 2023
Detection of infective endocarditis with [64Cu]Cu-DOTATATE positron emission tomography/computed tomography: a case
Katra Hadji-Turdeghal1, Marie Øbro Fosbøl2,3, Philip Hasbak2
1Department of Cardiology, Copenhagen University Hospital - Rigshospitalet, 2100 Copenhagen, Denmark.
Background:
Infective endocarditis (IE) is a serious and fatal condition, with prosthetic valve endocarditis representing the worst prognosis. The recommended nuclear imaging modality 2-deoxy-2-[18F]fluoro-D-glucose positron emission tomography/computed tomography ([18F]FDG PET/CT) has limitations. In this case series, we present two patients with IE scanned with a novel PET tracer [64Cu]Cu-DOTATATE ([64Cu]Cu-[1,4,7,10-tetraazacyclododecane-N,N',N″,N‴-tetra acetic acid]-d-Phe1, Tyr3-octreotate).
Case Summary:
An 84-year-old female patient (Patient 1) with a biological mitral valve prosthesis (MVP) was admitted acutely from the outpatient clinic. Transoesophageal echocardiography showed vegetations on the MVP. The patient underwent [64Cu]Cu-DOTATATE PET/CT, which showed uptake at the site of infection. The patient underwent surgical valve replacement. The post-operative period was without significant complications, and the patient was discharged home. In another case, a 72-year-old male patient (Patient 2) with a medical history of mild mitral valve stenosis, aortic valve stenosis, and gastrointestinal stromal tumour was admitted to the hospital for back and abdominal pain and subfebrile episodes. Transoesophageal echocardiography showed large vegetations in the native aortic valve. The patient underwent [64Cu]Cu-DOTATATE PET/CT, which showed no uptake at the site of the suspected infection. The patient underwent surgical valve replacement. The post-operative period was characterized by Candida albicans sternitis, and after prolonged hospitalization, the patient died of respiratory failure as a complication of sepsis.
Discussion:
In conclusion, this is the first case series presenting two patients with definite IE (modified Duke criteria), who were scanned with the novel [64Cu]Cu-DOTATATE PET/CT. Patient 1, with endocarditis in the MVP, showed an uptake of the tracer, while Patient 2, with native aortic valve endocarditis, did not show any uptake.
More Related Videos
Related Concept Videos
Radiological Investigation III: Pulmonary Angiogram and PET Scan
Pulmonary Angiogram
A Pulmonary Angiogram is an invasive procedure involving injecting a contrast medium through a catheter threaded into the pulmonary artery or the right side of the heart to visualize the pulmonary vasculature. Computed Tomography (CT) scans have mainly replaced this...
Positron Emission Tomography
One of the main requirements of a PET scan is a positron-emitting radioisotope, which is produced in a cyclotron and then attached to a substance used by the part of the body...
Imaging Studies II: Positron Emission Tomography and Scintigraphy
Fundamental Principles of PET
Imaging Studies for Cardiovascular System III: X-Ray
Definition and Purpose
An X-ray, or radiograph, is a non-invasive method that uses ionizing radiation to take images of internal structures. It is mainly used in cardiac imaging to examine the heart, lungs, and major blood vessels, aiming to identify abnormalities in the heart's size, shape, and position, such as heart failure, congenital defects, and vascular...
Imaging Studies for Cardiovascular System II:Types of Echocardiography
Types of Echocardiography
Transthoracic Echocardiography (TTE)
TTE is the most common type of echocardiogram which involves placing a transducer on the patient's chest, emitting sound waves to create heart images. TTE is invaluable for evaluating the heart's size, structure, and motion, making it particularly useful for...
Computed Tomography
The technique was invented in the 1970s and is based on the principle that as X-rays pass through the body, they are absorbed or reflected at different levels. In the technique, a patient lies on a motorized platform while a computerized axial tomography (CAT) scanner rotates...