Related Experiment Video
Updated: Jun 14, 2025

Author Spotlight: Implications of Non-Nutritive Sucking on Speech Emergence and Infant Development
Published on: April 19, 2024
An all-purpose method for optimal pressure sensor placement in water distribution networks based on graph signal
Xiao Zhou1, Xi Wan2, Shuming Liu3
1College of Civil Engineering, Hefei University of Technology, Hefei, China.
Abstract:
Many researchers have addressed the challenge of optimal pressure sensor placement for different purposes, such as leakage detection, model calibration, state estimation, etc. However, pressure data often need to serve multiple purposes, and a method to optimize sensor locations with versatility for various objectives is still lacking. In this paper, a graph-based optimal sensor placement (GOSP) framework is proposed, which aims to provide a robust and all-purpose approach to identify critical points for pressure monitoring. By analysing the spatial variation frequencies of WDN pressures, the relationship between measurements and the global variation of original pressures is established. On this basis, the D-optimality criterion is adopted to formulate the objective of GOSP, which aims to maximize the information on the spatial distribution of pressures that can be obtained from measurements. The new-proposed objective ensures that the sensor locations are compatible with various application scenarios. The proposed method was applied to a real-life distribution network, and was compared with other optimal sensor placement methods oriented towards burst detection and pipe roughness calibration. Based on comparative studies in different scenarios including unknown pressure estimation, burst detection, and model calibration, the effectiveness and robustness of the proposed method have been proved.
Related Concept Videos
Fluid Pressure
According to Pascal's law, a fluid at rest will generate equal pressure in all directions. This pressure is measured as a force per unit area, and its magnitude depends on the fluid's specific...
Bernoulli's Equation: Problem Solving
The first step is to compute the cross-sectional areas of the pipe and the Venturi throat to analyze the pressure difference indicated by the pressure gauge. Next, the continuity...
Pipe Flowrate Measurement
The orifice meter is a simple,...
Single Pipe Systems
In a Type I problem, fluid properties (density and viscosity), pipe characteristics (including diameter, length, and surface roughness), and the flow rate or average velocity are...
Pipe Flowrate Measurement: Problem Solving
Measurement of Fluid Pressure
A basic form of manometer is the piezometer, a vertical tube open at the top and filled with the same...

