Related Experiment Video
Updated: Jun 14, 2025

Preparation of Authigenic Pyrite from Methane-bearing Sediments for In Situ Sulfur Isotope Analysis Using SIMS
Published on: August 31, 2017
Analysis of sulfur in soil and plant digests using methane as a reaction gas for ICP-MS
Sukhjeet Singh1, Michael R Mucalo2, Megan N C Grainger2
1School of Science, The University of Waikato, Hamilton, New Zealand; Hill Laboratories, Hamilton, New Zealand.
Abstract:
Quantitation of sulfur (S) is vitally important for analysis of agricultural soil and plant samples due to the requirement of S in living organisms. Although inductively coupled plasma mass spectrometry (ICP-MS) is a commonly used and robust instrument for multi-elemental detection, S is usually analysed by ICP-optical emission spectroscopy (OES) since S quantitation poses a particular challenge for ICP-MS due to interferences on all S isotopes. The requirement for analysis by two instruments increases time and cost for sample analysis, hence analysis by one instrument is desirable. The use of reaction gases in ICP-MS can improve the performance by shifting S to a mass for detection where no interference is present. This work explored the potential of methane as a reaction gas for analysis of S in soil and plant samples to give users an alternative option to oxygen. The product ion clusters CH2SH+ were monitored (m/z 47 and 49 on ICP-MS and with mass shift of +15 from Q1 → Q2 using 32 → 47 and 34 → 49 on triple quadrupole ICP-MS). As expected, triple quadrupole ICP-MS performed better than single quadrupole ICP-MS containing a reaction cell due to the ability to preselect the m/z of choice and remove ions that may react with methane in the reaction cell. The method detection limit (MDL) was 150 mg kg-1 S for plants and 53 mg kg-1 S for soils which is fit for requirements. This is the first-time methane has been reported as a reaction gas for analysis of S and shows promising results for agricultural samples when using a triple quadrupole ICP-MS. Results compared well to those obtained via the more commonly used ICP-optical emission spectroscopy (OES) method with results <20 % for all samples. Interlaboratory comparison samples were within 2 Z-scores of the consensus mean. In the absence of ICP-MS/MS, Q-ICP-MS with detection of cluster m/z 47 was deemed to be suitable for detection of S in plant samples, with acceptable MDL (250 mg kg-1 S), acceptable precision (<20 % RSD) and <20 % variation to the reported ICP-OES result.
More Related Videos
Related Concept Videos
Inductively Coupled Plasma–Mass Spectrometry (ICP–MS): Overview
Sample Preparation for Analysis: Advanced Techniques
Acid digestion with strong acids is commonly used to dissolve inorganic materials that are insoluble (do not dissolve) in water. This method can be useful for...
The Sulfur Cycle
Mass Spectrum

