Prediction and analysis of relative error in electric vehicle charging stations based on an improved ConvFormer model

Liwen Chen1, Zhibin Liu1, Qingquan Yu1

  • 1Fujian University of Technology Institute of Ubiquitous Perception and Multi-sensor Integration Research, Fuzhou, Fujian Province, 350118, China.

Heliyon
|September 9, 2024
PubMed

Related Concept Videos

Transformers with Off-Nominal Turns Ratios01:25

Transformers with Off-Nominal Turns Ratios

In scenarios involving parallel transformers with disparate ratings, developing per-unit models requires accommodating off-nominal turns ratios. This situation arises when the selected base voltages are not proportional to the transformer’s voltage ratings. Consider a transformer where the rated voltages are related by the term a. If the chosen voltage bases satisfy a relationship involving term b, term c is defined as the ratio of these bases. This ratio is then substituted into the...
142
Power Factor Correction01:20

Power Factor Correction

The power transmission to a factory involves the transfer of apparent power, a combination of active and reactive power. The power factor measures how effectively electrical power is converted into useful work output. The ratio of the real power (KW) that does the work to the apparent power (KVA) supplied to the circuit.
161
Determining Electric Field From Electric Potential01:12

Determining Electric Field From Electric Potential

The electric field and electric potential are related to each other. If the electric field at various points in the region of interest is known, it can be used to calculate the electric potential difference between any two points. Similarly, if the electric potential is known for various points, then it is possible to calculate the electric field.
In general, regardless of whether the electric field is uniform, it points in the direction of decreasing potential because the force on a positive...
4.4K
Finding Electric Potential From Electric Field01:13

Finding Electric Potential From Electric Field

For a system of charges, it is easy to calculate the system's potential because potential is a scalar quantity. However, in some instances where calculating the electric field is more straightforward than finding the potential, the electric field is used to calculate the system's potential. For a positive charge, the electric field is radially outward, and the potential is positive at any finite distance from the positive charge. In such an electric field, the motion away from the...
4.0K
Energy Losses in Transformers01:21

Energy Losses in Transformers

In an ideal transformer, it is assumed that there are no energy losses, and, hence, all the power at the primary winding is transferred to the secondary winding. However, in reality,  the transformers always have some energy losses, and, hence, the output power obtained at the secondary winding is less than the input power at the primary winding due to energy losses.
There are four main reasons for energy losses in transformers.
The first cause can be  the high resistance of the...
843
The Power Flow Problem and Solution01:26

The Power Flow Problem and Solution

Power flow problem analysis is fundamental for determining real and reactive power flows in network components, such as transmission lines, transformers, and loads. The power system's single-line diagram provides data on the bus, transmission line, and transformer. Each bus k in the system is characterized by four key variables: voltage magnitude Vk​, phase angle δk​, real power Pk​, and reactive power Qk​. Two of these four variables are inputs, while the...
180