Christian Stadler1,2, Jonas Sebastian Bolm3, Clemens Schopper3,4
1Johannes Kepler University Linz, Altenberger Strasse 96, Linz, 4040, Austria. Christian.Stadler@kepleruniklinikum.at.
Introduction:
Implementing new approaches or new implants is always related with a certain learning curve in total hip arthroplasty (THA). Currently, many surgeons are switching to minimally invasive approaches combined with short stems for performing THA. Therefore, we aimed to asses and compare the learning curve of switching from an anterolateral Watson Jones approach (ALA) to a direct anterior approach (DAA) with the learning curve of switching from a neck-resecting to a partially neck-sparing short stem in cementless THA.
Materials And Methods:
The first 150 consecutive THA performed through a DAA (Group A) and the first 150 consecutive THA using a partially neck-sparing short stem (Group B) performed by a single surgeon were evaluated within this retrospective cohort study. All cases were screened for surgery related adverse events (AE). Furthermore, the operative time of each surgery was evaluated and the learning curve assessed performing a cumulative sum (CUSUM) analysis.
Results:
Overall, significantly more AE occurred in Group A compared to Group B (18.0% vs. 10.0%; p = 0.046). The sub-analysis of the AE revealed higher rates of periprosthetic joint infections (2.7% vs. 0.7%; p = 0.176), periprosthetic fractures (4.0% vs. 2.0%; p = 0.310) and overall revisions (4.7% vs. 1.3% p = 0.091) within Group A without statistical significance. The CUSUM analysis revealed a consistent reduction of operative time after 97 cases in Group A and 79 cases in Group B.
Conclusion:
A significantly higher overall rate of AE was detected while switching approach compared to switching implant for performing THA. However, according to the results of this study, surgeons should be aware of the learning curve of the adoption to a new implant with different fixation philosophy as well.