Related Experiment Video
Updated: Jun 13, 2025

Author Spotlight: Improving Radiation Therapy Access with Radiation Planning Assistant
Published on: October 6, 2023
Visualization of spatial dose distribution for effective radiation protection education in interventional radiology:
Yutaro Mori1,2,3,4, Tomonori Isobe5,6,7,8, Yasuwo Ide2,9
1Institute of Medicine, University of Tsukuba, 1-1-1 Tennodai, Tsukuba, Ibaraki, 305-8575, Japan.
Abstract:
In recent years, eye lens exposure among radiation workers has become a serious concern in medical X-ray fluoroscopy and interventional radiology (IVR), highlighting the need for radiation protection education and training. This study presents a method that can maintain high accuracy when calculating spatial dose distributions obtained via Monte Carlo simulation and establishes another method to three-dimensionally visualize radiation using the obtained calculation results for contributing to effective radiation-protection education in X-ray fluoroscopy and IVR. The Monte Carlo particle and heavy ion transport code system (PHITS, Ver. 3.24) was used for calculating the spatial dose distribution generated by an angiography device. We determined the peak X-ray tube voltage and half value layer using Raysafe X2 to define the X-ray spectrum from the source and calculated the X-ray spectrum from the measured results using an approximation formula developed by Tucker et al. Further, we performed measurements using the "jungle-gym" method under the same conditions as the Monte Carlo calculations for verifying the accuracy of the latter. An optically stimulated luminescence dosimeter (nanoDot dosimeter) was used as the measuring instrument. In addition, we attempted to visualize radiation using ParaView (version 5.12.0-RC2) using the spatial dose distribution confirmed by the above calculations. A comparison of the measured and Monte Carlo calculated spatial dose distributions revealed that some areas showed large errors (12.3 and 24.2%) between the two values. These errors could be attributed to the scattering and absorption of X-rays caused by the jungle gym method, which led to uncertain measurements, and (2) the angular and energy dependencies of the nanoDot dosimetry. These two causes explain the errors in the actual values, and thus, the Monte Carlo calculations proposed in this study can be considered to have high-quality X-ray spectra and high accuracy. We successfully visualized the three-dimensional spatial dose distribution for direct and scattered X-rays separately using the obtained spatial dose distribution. We established a method to verify the accuracy of Monte Carlo calculations performed through the procedures considered in this study. Various three-dimensional spatial dose distributions were obtained with assured accuracy by applying the Monte Carlo calculation (e.g., changing the irradiation angle and adding a protective plate). Effective radiation-protection education can be realized by combining the present method with highly reliable software to visualize dose distributions.
More Related Videos
07:57Positron Emission Tomography-based Dose Painting Radiation Therapy in a Glioblastoma Rat Model using the Small Animal Radiation Research Platform
Published on: March 24, 2022
08:25Radiation Planning Assistant - A Streamlined, Fully Automated Radiotherapy Treatment Planning System
Published on: April 11, 2018
Related Concept Videos
Radiological Investigation III: Pulmonary Angiogram and PET Scan
Pulmonary Angiogram
A Pulmonary Angiogram is an invasive procedure involving injecting a contrast medium through a catheter threaded into the pulmonary artery or the right side of the heart to visualize the pulmonary vasculature. Computed Tomography (CT) scans have mainly replaced this...
Radiological Investigation I: X-ray and CT
Positron Emission Tomography
One of the main requirements of a PET scan is a positron-emitting radioisotope, which is produced in a cyclotron and then attached to a substance used by the part of the body...
X-ray Imaging
Imaging Studies for Cardiovascular System III: X-Ray
Definition and Purpose
An X-ray, or radiograph, is a non-invasive method that uses ionizing radiation to take images of internal structures. It is mainly used in cardiac imaging to examine the heart, lungs, and major blood vessels, aiming to identify abnormalities in the heart's size, shape, and position, such as heart failure, congenital defects, and vascular...
Biological Effects of Radiation