Related Experiment Video
Updated: Jun 13, 2025

Author Spotlight: Advancements in Refractive Surgical Correction for Presbyopia and Exploring Postoperative Visual Acuity
Published on: September 20, 2024
Jacobi-Fourier phase masks as ophthalmic elements to correct presbyopia
Ángel Salas-Sanchez1, Enrique González-Amador1, Alfonso Padilla-Vivanco1
1Universidad Politécnica de Tulancingo, Tulancingo, Hidalgo, Mexico.
Purpose:
Investigations into the correction of presbyopia have considered lens design, clinical implications and the development of objective metrics such as the visual Strehl ratio. This study investigated the Jacobi-Fourier phase mask as an ophthalmic element in the correction of presbyopia. The goal was to develop a contact or intraocular lens whose performance was largely insensitive to changes in pupil diameter.
Methods:
Numerical simulations based on Fourier optics were performed to evaluate three different Jacobi-Fourier polynomials, with the aim of providing a range of clear vision (1 Dioptre (D)). Performance was evaluated for three pupil sizes (6, 4 and 2 mm), while polychromatic images were simulated using three different wavelengths (656.3, 587.6 and 486.1 nm). The Neural Transfer function was included in the simulation. To validate the method and results, we used the Visual Strehl combined objective metric (VSCombined) currently used in visual optics. This metric gives more weight to the phase transfer function and is more suitable for non-symmetrical phase functions.
Results:
Numerical validation showed the suitability of the Jacobi-Fourier phase masks for extending the range of clear vision of presbyopic eyes, providing a visual acuity of at least 0.10 logMAR (6/7.5 Snellen) at all distances between 1 and 6 m. The results show a range of clear vision of 1D was not affected by changes in pupil size, an increase in retinal image contrast accompanied by image artefact reduction by increasing the radial order of the Jacobi-Fourier phase mask and a reduction of wavelength dependence of the retinal images. These results are supported by simulated images and the objective criterion VSCombined.
Conclusions:
The use of Jacobi-Fourier phase masks as ophthalmic elements for presbyopic correction show promising results, with a good range of clear vision and reduced dependence on pupil size and chromatic aberration.
Related Concept Videos
Focusing of Light in the Eye
Distance Corrections
Power Factor Correction
Inverse z-Transform by Partial Fraction Expansion
To begin the process, the poles of the function are identified and the function is...
Linear Approximation in Frequency Domain
In contrast, nonlinear systems do not inherently possess these properties. However, for small deviations around an operating point, a nonlinear system can often be approximated as linear....
Trigonometric Fourier series
The trigonometric Fourier series specifically expresses a periodic function with a defined period T using sine...

