Related Experiment Video
Updated: Sep 29, 2026

Expired CO2 Measurement in Intubated or Spontaneously Breathing Patients from the Emergency Department
Published on: January 30, 2011
Continuous transcutaneous O2 and CO2 monitoring during conscious sedation for oral surgery
Abstract:
Continuous transcutaneous oxygen and carbon dioxide monitoring during conscious sedation using diazepam, fentanyl, and methohexital indicates that hypoxia occurs in all patients maintained on room air; 36% of the patients maintained on room air showed a decrease in transcutaneous oxygen of greater than 20 mg Hg. Although the use of supplemental O2 prevented hypoxia, the combination of diazepam, fentanyl, and methohexital depressed all of the patient's carbon dioxide chemoreceptors, resulting in a rise in carbon dioxide in the oxygen-supplemented patients as well as in the patients who were maintained on room air. The need for supplemental oxygen in patients sedated with diazepam, fentanyl, and methohexital is clearly established.
More Related Videos
07:54Drug-Induced Sleep Endoscopy (DISE) with Target Controlled Infusion (TCI) and Bispectral Analysis in Obstructive Sleep Apnea
Published on: December 6, 2016
07:51Evaluation of Capnography Sampling Line Compatibility and Accuracy when Used with a Portable Capnography Monitor
Published on: September 29, 2020
Related Concept Videos
Assessment of Diffusion and Perfusion
The Role of Diffusion in Respiration
Diffusion is the process by which molecules move from an area of higher concentration to an area of lower concentration. In the respiratory system, this principle...
Special considerations while measuring oxygen saturation
Ensuring accuracy in vital sign recordings while prioritizing patient comfort and minimizing anxiety is important.
Stages of General Anesthesia
Pulse Oximetry
Purpose
Average SpO2 values are greater than 95%. If the readings fall below 90%, it indicates that...
Oxygen Delivering System I: Nasal Cannula and Face Mask
Nasal Cannula
A nasal cannula is a lightweight tube split at one end into two prongs and placed in the nostrils. It is typically used to deliver low to medium levels of oxygen.
Suggested flow rate: The suggested flow rate for a nasal cannula typically ranges between 1 and 6 L/min.
Oxygen percentage setting:...
Oxygen Delivering System II: Venturi Mask and Transtracheal Oxygen
Venturi Mask
The Venturi mask, named after the Venturi effect, is designed to deliver precise oxygen concentrations. It consists of a large tube with an oxygen inlet that narrows down, causing a pressure drop that pulls air in through adjustable side ports. The mask is a lightweight,...