A randomized trial on the effect of tubing changes on hub contamination and catheter sepsis during parenteral

Insights

Changing central venous catheter tubing less frequently (every 4 days) does not increase catheter-related sepsis or hub contamination. This finding, combined with proper hub protection, helps control sepsis outbreaks.

Area of Science:

  • Infectious Diseases
  • Medical Devices
  • Clinical Trials

Background:

  • Catheter hub contamination is a primary cause of catheter-related sepsis.
  • Frequent manipulation during tubing changes may elevate contamination risks.

Purpose of the Study:

  • To evaluate the impact of tubing replacement frequency on hub colonization and catheter sepsis.
  • To compare findings with historical data from a coagulase-negative staphylococci outbreak.

Main Methods:

  • A prospective trial randomized 52 patients into two groups: 2-day (Group A) and 4-day (Group B) tubing replacements.
  • Quantitative cultures of catheter tips and hubs were performed post-removal.
  • Results were compared to historical data from a sepsis outbreak.

Main Results:

  • Hub colonization and infection rates were similar between the 2-day and 4-day replacement groups.
  • Catheter sepsis rates were significantly lower in the trial groups (5.7%) compared to historical data (40%).
  • Hub colonization infection rates were also significantly lower in the trial (19%) versus historical (50%) data.

Conclusions:

  • Less frequent tubing changes (every 4 days) do not increase catheter sepsis or hub contamination.
  • Adequate hub protection and less frequent tubing changes are effective in controlling catheter-related sepsis outbreaks.