The reliability of virtual non-contrast reconstructions of photon-counting detector CT scans in assessing abdominal
Ibolyka Dudás1, Leona Schultz1, Márton Benke2
1Department of Radiology, Medical Imaging Centre, Semmelweis University, 2 Korányi Sándor St, Budapest, H-1083, Hungary.
Background:
Spectral imaging of photon-counting detector CT (PCD-CT) scanners allows for generating virtual non-contrast (VNC) reconstruction. By analyzing 12 abdominal organs, we aimed to test the reliability of VNC reconstructions in preserving HU values compared to real unenhanced CT images.
Methods:
Our study included 34 patients with pancreatic cystic neoplasm (PCN). The VNC reconstructions were generated from unenhanced, arterial, portal, and venous phase PCD-CT scans using the Liver-VNC algorithm. The observed 11 abdominal organs were segmented by the TotalSegmentator algorithm, the PCNs were segmented manually. Average densities were extracted from unenhanced scans (HUunenhanced), postcontrast (HUpostcontrast) scans, and VNC reconstructions (HUVNC). The error was calculated as HUerror=HUVNC-HUunenhanced. Pearson's or Spearman's correlation was used to assess the association. Reproducibility was evaluated by intraclass correlation coefficients (ICC).
Results:
Significant differences between HUunenhanced and HUVNC[unenhanced] were found in vertebrae, paraspinal muscles, liver, and spleen. HUVNC[unenhanced] showed a strong correlation with HUunenhanced in all organs except spleen (r = 0.45) and kidneys (r = 0.78 and 0.73). In all postcontrast phases, the HUVNC had strong correlations with HUunenhanced in all organs except the spleen and kidneys. The HUerror had significant correlations with HUunenhanced in the muscles and vertebrae; and with HUpostcontrast in the spleen, vertebrae, and paraspinal muscles in all postcontrast phases. All organs had at least one postcontrast VNC reconstruction that showed good-to-excellent agreement with HUunenhanced during ICC analysis except the vertebrae (ICC: 0.17), paraspinal muscles (ICC: 0.64-0.79), spleen (ICC: 0.21-0.47), and kidneys (ICC: 0.10-0.31).
Conclusions:
VNC reconstructions are reliable in at least one postcontrast phase for most organs, but further improvement is needed before VNC can be utilized to examine the spleen, kidneys, and vertebrae.
More Related Videos
06:33Construction of a Preclinical Multimodality Phantom Using Tissue-mimicking Materials for Quality Assurance in Tumor Size Measurement
Published on: July 29, 2013
12:32Image Rendering Techniques in Postmortem Computed Tomography: Evaluation of Biological Health and Profile in Stranded Cetaceans
Published on: September 27, 2020
Related Concept Videos
Computed Tomography
The technique was invented in the 1970s and is based on the principle that as X-rays pass through the body, they are absorbed or reflected at different levels. In the technique, a patient lies on a motorized platform while a computerized axial tomography (CAT) scanner rotates...
Radiological Investigation I: X-ray and CT
Imaging Studies III: Gastrointestinal Motility Studies and Virtual Colonoscopy
Radionuclide Testing
Radionuclide testing is a sophisticated medical technique for assessing gastrointestinal motility. It focuses on gastric emptying and colonic transit time. Radioactive markers track the movement of food through the digestive system, providing insights into gastrointestinal disorders.
In gastric emptying studies, a meal's liquid and...
Imaging Studies II: Positron Emission Tomography and Scintigraphy
Fundamental Principles of PET
Imaging Studies I: CT and MRI
Description of the Procedures
Computed Tomography (CT) scan:
Computed Tomography (CT) scans use X-ray technology to generate detailed images of bones, organs, and tissues. During the scan, the patient lies on a moving table...