Related Experiment Video
Updated: Jun 13, 2025

Development of a Gaze-Contingent Display Framework Designed for Perceptual and Oculomotor Research with Simulated Central Vision Loss
Published on: April 11, 2025
Advancing Glaucoma Diagnosis: Employing Confidence-Calibrated Label Smoothing Loss for Model Calibration
Midhula Vijayan1, Deepthi Keshav Prasad1, Venkatakrishnan Srinivasan1
1Research and Development, Forus Health Pvt. Ltd., Bengaluru, Karnataka, India.
Objective:
The aim of our research is to enhance the calibration of machine learning models for glaucoma classification through a specialized loss function named Confidence-Calibrated Label Smoothing (CC-LS) loss. This approach is specifically designed to refine model calibration without compromising accuracy by integrating label smoothing and confidence penalty techniques, tailored to the specifics of glaucoma detection.
Design:
This study focuses on the development and evaluation of a calibrated deep learning model.
Participants:
The study employs fundus images from both external datasets-the Online Retinal Fundus Image Database for Glaucoma Analysis and Research (482 normal, 168 glaucoma) and the Retinal Fundus Glaucoma Challenge (720 normal, 80 glaucoma)-and an extensive internal dataset (4639 images per category), aiming to bolster the model's generalizability. The model's clinical performance is validated using a comprehensive test set (47 913 normal, 1629 glaucoma) from the internal dataset.
Methods:
The CC-LS loss function seamlessly integrates label smoothing, which tempers extreme predictions to avoid overfitting, with confidence-based penalties. These penalties deter the model from expressing undue confidence in incorrect classifications. Our study aims at training models using the CC-LS and comparing their performance with those trained using conventional loss functions.
Main Outcome Measures:
The model's precision is evaluated using metrics like the Brier score, sensitivity, specificity, and the false positive rate, alongside qualitative heatmap analyses for a holistic accuracy assessment.
Results:
Preliminary findings reveal that models employing the CC-LS mechanism exhibit superior calibration metrics, as evidenced by a Brier score of 0.098, along with notable accuracy measures: sensitivity of 81%, specificity of 80%, and weighted accuracy of 80%. Importantly, these enhancements in calibration are achieved without sacrificing classification accuracy.
Conclusions:
The CC-LS loss function presents a significant advancement in the pursuit of deploying machine learning models for glaucoma diagnosis. By improving calibration, the CC-LS ensures that clinicians can interpret and trust the predictive probabilities, making artificial intelligence-driven diagnostic tools more clinically viable. From a clinical standpoint, this heightened trust and interpretability can potentially lead to more timely and appropriate interventions, thereby optimizing patient outcomes and safety.
Financial Disclosures:
Proprietary or commercial disclosure may be found in the Footnotes and Disclosures at the end of this article.
Related Concept Videos
Glaucoma: Overview
Open Angle Glaucoma: Treatment
Drugs such as carbonic anhydrase inhibitors, α2- and...
Angle Closure Glaucoma: Treatment

