RETRACTED: Evaluating cardiac risks of TASER: An in-depth case study through probable current analysis
Hojeong Seo1, Saehan Park1, Sanghee Kim2
1Division of Forensic Engineering, National Forensic Service, Wonju, Korea.
TASER discharges pose cardiac risks, potentially causing ventricular fibrillation (VF). This study highlights dart impact location as crucial for evaluating TASER safety and preventing fatalities.
Area of Science:
- Forensic Science
- Cardiology
- Biomedical Engineering
Background:
- TASER devices are widely used for law enforcement.
- Concerns exist regarding the cardiac safety of TASER discharges.
- The first TASER-related fatality in South Korea prompted this investigation.
Observation:
- A case study involving a TASER-related fatality was analyzed.
- High-resolution waveform analysis and forensic examination of dart impact sites were performed.
- A human body impedance model of 500Ω was used, incorporating IEC 60479 standards.
Findings:
- Ventricular fibrillation (VF) risk was evaluated using Pratt et al.'s framework.
- Calculated VF risk reached up to 5%, contingent on dart impact location and current pathways.
- While not exceeding critical thresholds in the specific case, the VF risk was significant.
Implications:
- Dart impact location is a critical factor in TASER cardiac safety assessments.
- TASER discharges may contribute to fatal outcomes, emphasizing the need for safety protocols.
- This research informs broader understanding of TASER cardiac risks and safety recommendations.