Simultaneous Electrocardiography Recording and Invasive Blood Pressure Measurement in Rats
Published on: January 31, 2019
Measurement of blood pressure in rats: Invasive or noninvasive methods?
Viktória Kapsdorferová1, Soňa Grešová1, Pavol Švorc1
1Department of Medical Physiology, Faculty of Medicine, Pavol Jozef Safarik University, Kosice, Slovakia.
Abstract:
Experiments should always be based on control values. This assumption fully applies to cardiovascular parameters, such as heart rate (HR) and blood pressure (BP), which are highly sensitive to various external and internal stimuli and can already be significantly altered when an experiment begins. Therefore, it is necessary to determine which values are defined as a starting point (i.e., control and baseline) or compare them with valid reference values if the goal is to evaluate the changes after experimental intervention. A generally accepted principle is a reciprocal relationship between BP and HR, in which one parameter affects the other and vice versa. BP can be measured using two methods-noninvasively (tail-cuff) and invasively (telemetry, direct measurements of BP after introducing the sensor directly into the artery), and HR directly or by extrapolation from BP recordings. This study does not aim to evaluate the results of individual studies, but to review whether there are differences in control (baseline) BP values in normotensive and hypertensive male rats using invasive versus noninvasive methods, and to investigate whether there is a causal relationship between BP and HR in in vivo experiments with male rats.
More Related Videos
08:54Measuring Blood Pressure in Mice using Volume Pressure Recording, a Tail-cuff Method
Published on: May 15, 2009
09:38Femoral Arterial and Venous Catheterization for Blood Sampling, Drug Administration and Conscious Blood Pressure and Heart Rate Measurements
Published on: January 24, 2012
Related Concept Videos
Equipments Used To Measure Blood Pressure
This invasive approach involves cannulating a peripheral artery. During each cardiac contraction, pressure generates mechanical motion within the catheter, transmitted through rigid, fluid-filled tubing to a transducer. This transducer converts mechanical motion into electrical signals displayed as waveforms on a monitor. An automatic flushing system prevents blood backflow. Due to the potential risk of unexpected arterial blood loss, this method is primarily used in intensive...
Measurement of Blood Pressure
Sites for measruring blood pressure
The Brachial Artery: Primary Site for Blood Pressure Measurement
Assessment of blood pressure in brachial artery(two-step method)