Validation of an Optical Technology for the Determination of pH in Milk during Yogurt Manufacture
Siqi Liu1, Fanny Contreras2, Ricardo S Alemán3
1Centre d'Innovació, Recerca i Transferència en Tecnologia dels Aliments (CIRTTA), Departament de Ciència Animal i dels Aliments, Facultat de Veterinària, Universitat Autònoma de Barcelona, 08193 Bellaterra, Spain.
Abstract:
Current systems that allow inline pH control in the fermented dairy industry have drawbacks, such as protein adhesion on the non-glass pH probes, measurement distortion, frequent recalibration needs, and sensitivity to extreme pH conditions encountered during clean-in-place operations. Therefore, the objective of this study was to validate the feasibility of estimating the pH of milk during the yogurt making process by using a NIR light backscatter sensor measuring under different fermentation temperatures and milk protein concentrations using a mathematical model that correlates the light scatter signal with pH. Three replications of the experiment with two protein concentrations (3.5 and 4.0%) and two fermentation temperatures (43 and 46 °C) were used to validate this inline pH prediction model. Continuous and discontinuous measurements of pH were collected as a reference during fermentation, simultaneously with the light backscatter data acquisition. Also, the effect of adjusting the initial voltage gain of the light scatter device on the accuracy of the pH prediction model was evaluated. Temperature and initial voltage were the main factors affecting the fitting accuracy of the model. The adjustment of the initial voltage gain improved the pH prediction model fit. The model has been successfully validated for both continuous and discontinuous measurements of pH, with SEP values < 0.09 pH units and CV < 1.78%. The proposed optical inline and non-destructive method was feasible for inline pH monitoring of milk fermentation, avoiding traditional manual pH measurement.
More Related Videos
08:43PTR-ToF-MS Coupled with an Automated Sampling System and Tailored Data Analysis for Food Studies: Bioprocess Monitoring, Screening and Nose-space Analysis
Published on: May 11, 2017
08:38Novel Production Protocol for Small-scale Manufacture of Probiotic Fermented Foods
Published on: September 10, 2016
Related Concept Videos
Indicators
Titration of a Weak Acid with a Weak Base
As a result, there is no simple...
Data Validation
Key parameters for method validation include:
Titration Calculations: Strong Acid - Strong Base
A titration is carried out for 25.00 mL of 0.100 M HCl (strong acid) with 0.100 M of a strong base NaOH. The pH at different volumes of added base solution can be calculated as follows:
(a) Titrant volume = 0 mL. The solution pH is due to the acid ionization of HCl. Because this is a strong acid, the ionization is complete and the hydronium ion molarity is 0.100 M. The pH of the solution is then:
Titration of Polyprotic Base with a Strong Acid