Accuracy in Dental Medicine, A New Way to Measure Trueness and Precision
Published on: April 29, 2014
Dimensional Accuracy of Novel Vinyl Polysiloxane Compared with Polyether Impression Materials: An In Vitro Study
Moritz Waldecker1, Stefan Rues1, Peter Rammelsberg1
1Department of Prosthetic Dentistry, University Hospital Heidelberg, University of Heidelberg, 69120 Heidelberg, Germany.
Dental impression materials, vinyl polysiloxane (VPS) and polyether (PE), with single-step techniques show clinically acceptable accuracy for fabricating restorations. Both materials and techniques provide precise local accuracy for abutment teeth.
Area of Science:
- Dentistry
- Dental Materials Science
- Prosthodontics
Background:
- Accurate intraoral impressions are vital for precise dental restoration fabrication.
- Vinyl polysiloxane (VPS) and polyether (PE) are common impression materials.
- Impression techniques, including mono-phase and dual-phase single step, influence accuracy.
Purpose of the Study:
- To compare the dimensional accuracy of hydrophilic quadrofunctional VPS and PE impression materials.
- To evaluate the impact of mono-phase and dual-phase single-step impression techniques on accuracy.
- To assess the clinical acceptability of different material and technique combinations.
Main Methods:
- A reference model simulating a partially edentulous mandible was used.
- Stainless-steel precision balls measured dimensional deviations.
- Four test groups were evaluated: VPS mono-phase, PE mono-phase, VPS dual-phase, and PE dual-phase.
- Global and local accuracy (trueness and precision) were statistically analyzed using ANOVA.
Main Results:
- All tested distances were underestimated, with cross-arch distances showing the highest global inaccuracies (-82 µm to -109 µm).
- Excellent local accuracy was observed for abutment tooth surfaces (crown surface trueness < 10 µm, precision < 12 µm) across all groups.
- Inlay surfaces exhibited higher inaccuracies (trueness < 15 µm, precision < 26 µm).
Conclusions:
- All evaluated impression materials (VPS, PE) and techniques (mono-phase, dual-phase single step) yield clinically acceptable accuracy for dental models.
- Local accuracy for abutment tooth surfaces is highly reliable with these materials and techniques.
- While global accuracy has limitations, particularly for cross-arch distances, the overall results support their clinical use.
Related Concept Videos
Polymers: Molecular Weight Distribution
Polymer Classification: Stereospecificity
Molecular Weight of Step-Growth Polymers
As the step-growth polymerization involves step-wise condensation of monomers, the molecular weight also builds up eventually. Consequently, high molecular weight polymers are obtained at the late stages of the polymerization, where 99% of monomers have been consumed.
The extent of the...
Types of Step-Growth Polymers: Polyesters
Polyesters are commonly prepared from terephthalic acid and ethylene glycol; the crude product is known as poly(ethylene terephthalate) or PET. However, polyesters are synthesized industrially by transesterification of dimethyl terephthalate with ethylene glycol at 150 °C. The two reactants and the polymer...
Classification and Mechanical Properties of Synthetic Polymers