Abstract:
There is an urgent need to measure the motivation to taste a sweet fluid in order to determine the influence of sweet tastes on the potential choices and consumption of beverages in patients with obesity. Current methods utilize either survey instruments or arbitrary operant tasks. The sipometer enables the participant to utilize an actual ingestive behavioral response to measure motivation during access to beverages on either ad libitum (AL) or progressive time ratio (PR) schedules. We determined the sipometer's responsiveness and reliability as a test of change in motivation for sweet tastes after bariatric surgery. Participants (58 patients and 28 controls, BMI: 18.5-24.9 kg/m2) sham-consumed an aspartame-sweetened (S) and non-sweetened (N) beverage under AL and PR schedules at a pre-surgery/baseline and a 3-month and 24-month visit (patients only). Cumulative pressure (CumPres), a measure of effort, was the sum of the pressures exerted during sipping under each condition. Baseline CumPres for PRS was higher than ALS and ALN in patients (p < 0.03) and higher than PRN in controls (p = 0.009). At 3 months, CumPres did not differ amongst conditions in patients, but CumPres for PRS was higher than all other conditions in controls (p < 0.0005). There were no baseline group differences; however, patients' CumPres for PRS was lower than controls' at 3 months (p = 0.002). Patients' CumPres for PRS decreased non-significantly between the baseline and 3 months but increased at 24 months compared to 3 months (p = 0.025) and was no different from baseline. Controls' CumPres for PRS increased at 3 months (p = 0.0359), but CumPres for all conditions was correlated between visits (p's < 0.038). The sipometer is a reliable and sensitive measure of motivation to consume sweet beverages and may reflect changes in post-operative energy intake.
Related Concept Videos
Equipments Used To Measure Blood Pressure
This invasive approach involves cannulating a peripheral artery. During each cardiac contraction, pressure generates mechanical motion within the catheter, transmitted through rigid, fluid-filled tubing to a transducer. This transducer converts mechanical motion into electrical signals displayed as waveforms on a monitor. An automatic flushing system prevents blood backflow. Due to the potential risk of unexpected arterial blood loss, this method is primarily used in intensive...
Assessment of the Abdomen III: Palpation
Assessment of the Abdomen I: Inspection and Auscultation
The abdominal examination is a cornerstone of clinical medicine, serving as a critical tool in diagnosing various gastrointestinal (GI) diseases. It involves a systematic approach that includes inspection and auscultation, each with distinct yet complementary roles in assessing the abdomen. This article will delve into these two primary methods healthcare professionals use to examine the abdomen.
Inspection of the Abdomen
The first step in any abdominal examination is inspection.
Assessment of the Abdomen II: Percussion
Percussion
Percussion is an essential...