Related Experiment Video
Updated: Jun 13, 2025

Data Acquisition Protocol for Determining Embedded Sensitivity Functions
Published on: April 20, 2016
Optimal Sensor Placement for Enhanced Efficiency in Structural Health Monitoring of Medium-Rise Buildings
Salman Saeed1,2, Sikandar H Sajid2,3, Luc Chouinard2
1National Institute of Urban Infrastructure Planning, University of Engineering & Technology, Peshawar 25000, Pakistan.
Abstract:
Output-only modal analysis using ambient vibration testing is ubiquitous for the monitoring of structural systems, especially for civil engineering structures such as buildings and bridges. Nonetheless, the instrumented nodes for large-scale structural systems need to cover a significant portion of the spatial volume of the test structure to obtain accurate global modal information. This requires considerable time and resources, which can be challenging in large-scale projects, such as the seismic vulnerability assessment over a large number of facilities. In many instances, a simple center-line (stairwell case) topology is generally used due to time, logistical, and economic constraints. The latter, though a fast technique, cannot provide complete modal information, especially for torsional modes. In this research, corner-line instrumented nodes layouts using only a reference and a roving sensor are proposed, which overcome this issue and can provide maximum modal information similar to that from 3D topologies for medium-rise buildings. Parametric studies are performed to identify the most appropriate locations for sensor placement at each floor of a medium-rise building. The results indicate that corner locations at each floor are optimal. The proposed procedure is validated through field experiments on two medium-rise buildings.
Related Concept Videos
Design Example: Sustainability in Concrete Building
There are multiple approaches to achieve sustainability in a commercial concrete building. For instance, construct a concrete parking area under the building, utilizing pervious concrete paver blocks in open areas to facilitate rainwater collection through an underground...
Unsymmetric Loading of Thin-Walled Members
The concept of the shear center is crucial in countering the...
Design Example: Identifying the Locations of Monuments in the Field Using Global Positioning System Device
Posttensioned Masonry Walls
Post-tensioned masonry walls use high-strength steel rods or flexible tendons to enhance the strength and efficiency of masonry structures. These elements are securely anchored to the foundation and extend vertically either within the cores of the masonry units or between the masonry wythes. The construction process involves building the wall with these tensioning elements in place and allowing the mortar to fully cure.
Following the curing process, the tensioning begins. Steel rods are...

