Related Experiment Video
Updated: Jun 13, 2025

08:12
Calculating Heart Rate Variability from ECG Data from Youth with Cerebral Palsy During Active Video Game Sessions
Published on: June 5, 2019
19.8K
Validity and Reliability of Movesense HR+ ECG Measurements for High-Intensity Running and Cycling
Raúl Martín Gómez1, Enzo Allevard2, Haye Kamstra3
1School of Physical Education, Sport and Exercise Sciences, University of Otago, Dunedin 9054, New Zealand.
Sensors (Basel, Switzerland)
|September 14, 2024
Summary
The Movesense HR+ ECG device offers accurate and reliable heart rate measurements, outperforming the Garmin HRM-Pro in validity tests. This makes it a cost-effective tool for athletes and practitioners seeking precise physiological data.
Area of Science:
- Sports Science
- Biomedical Engineering
- Physiological Monitoring
Background:
- Accurate physiological measurements are crucial for athletes and coaches.
- Low-cost, portable devices are needed for widespread adoption.
- Existing devices vary in accuracy and reliability.
Purpose of the Study:
- To validate and assess the reliability of Movesense HR+ ECG measurements against a criterion three-lead ECG.
- To compare the performance of Movesense HR+ with the Garmin HRM device.
- To develop and refine algorithms for accurate R-peak detection.
Main Methods:
- Twenty-one healthy adults underwent incremental running and cycling tests to exhaustion.
- Participants completed tests with rest periods before and after.
- Movesense HR+ and Garmin HRM data were compared to a criterion three-lead ECG using Bland-Altman analysis and correlation coefficients.
Main Results:
- Movesense HR+ demonstrated high sensitivity (99.7%) and precision (99.6%) for R-peak detection compared to the criterion.
- Garmin HRM showed lower sensitivity (84.7%) and precision (87.7%).
- Bland-Altman analysis indicated minimal mean differences for Movesense HR+ (0.23 ms at rest, 0.38 ms during exercise), while Garmin HRM showed larger differences (-8.5 ms at rest, 27.7 ms during exercise).
- Correlation between Movesense HR+ and criterion was very strong (r=0.98) during exercise, versus moderate for Garmin HRM (r=0.66).
Conclusions:
- Movesense HR+ is a valid and reliable device for ECG measurement, suitable for athletes and practitioners.
- The developed R-peak detection algorithm and data collection protocol enhance Movesense HR+ accuracy.
- Movesense HR+ offers a superior cost-effective alternative to other devices for physiological monitoring.
Keywords:
ECG measurementsGarmin HRM-ProMovesense HR+R-peak detectionexercise intensityheart rate variability (HRV)reliabilitysports sciencevaliditywearable devicesMore Related Videos
Related Concept Videos
Electrocardiogram
2.2K
An electrocardiogram (ECG or EKG) is a critical diagnostic tool that records the electrical signals produced by the heart during each heartbeat. This recording is achieved through electrodes placed strategically on the arms, legs, and chest. The electrocardiograph amplifies these signals and produces 12 distinct tracings, offering a comprehensive understanding of the heart's electrical activity.
Three major waveforms are present in a typical ECG recording: the P wave, the QRS complex, and...
Three major waveforms are present in a typical ECG recording: the P wave, the QRS complex, and...
2.2K
Exercise Stress Test
178
Introduction
Exercise stress testing, commonly known as a treadmill test, is a noninvasive procedure used to evaluate cardiovascular function and diagnose heart conditions.
Definition
An exercise stress test measures the heart's response to exertion using a treadmill or stationary bicycle. Chest electrodes record the heart's electrical activity through an ECG, and blood pressure is monitored regularly.
Purposes
Exercise stress testing, commonly known as a treadmill test, is a noninvasive procedure used to evaluate cardiovascular function and diagnose heart conditions.
Definition
An exercise stress test measures the heart's response to exertion using a treadmill or stationary bicycle. Chest electrodes record the heart's electrical activity through an ECG, and blood pressure is monitored regularly.
Purposes
178