GA-BP-Based Low-Noise FBG Hydroacoustic Monitoring System with Reference Sensor
Yubin Zhou1,2, Yuexia Zhao1, Chengbing Song1
1National Deep Sea Center of China, Qingdao 266237, China.
Abstract:
To address the issue of harsh marine background noise impacting the monitoring signal of fiber-optic hydrophones, we propose a low-noise fiber Bragg grating (FBG) hydroacoustic monitoring system with a reference sensor based on genetic algorithm backpropagation (GA-BP). Through theoretical analysis, we deduce the noise suppression steps of the GA-BP algorithm based on the reference sensor and construct train and test sets based on the data from the reference sensor and monitoring sensor at different times, optimizing the GA-BP algorithm to find the best fitting results and thereby obtaining the low-noise monitoring signal. Experimental results from the anechoic tank show that the proposed method can suppress background noise interference on effective signals and that the suppression effect improves as the background noise increases. The sound pressure sensitivity ranges from -173.76 dB to -171.33 dB at frequencies of 8 kHz to 12 kHz, with a response flatness of less than 2.43 dB. The noise suppression effect is obvious under the condition of poor signal-to-noise ratio (SNR), which can reach more than 18.3 dB. The advantages of the proposed algorithm in array signal processing are further demonstrated by the directivity experiment, which proves that the algorithm has a great potential for engineering applications in harsh marine environment.
Related Concept Videos
Equipments Used To Measure Blood Pressure
This invasive approach involves cannulating a peripheral artery. During each cardiac contraction, pressure generates mechanical motion within the catheter, transmitted through rigid, fluid-filled tubing to a transducer. This transducer converts mechanical motion into electrical signals displayed as waveforms on a monitor. An automatic flushing system prevents blood backflow. Due to the potential risk of unexpected arterial blood loss, this method is primarily used in intensive...
Assessing Blood pressure using a doppler ultrasound
Pre-Procedural Guidelines for Doppler Ultrasound Blood Pressure Assessment:
Preparation of Equipment:
Measurement of Fluid Pressure
A basic form of manometer is the piezometer, a vertical tube open at the top and filled with the same...