Intrapartum ultrasound for cervical dilatation: Inter- and intra-observer agreement
Arwa Hanidu1,2, Mariya Kovalenko1,2, Sana Usman1,2
1Queen Charlotte's and Chelsea Hospital, Imperial Healthcare NHS Trust, London, UK.
Introduction:
Digital vaginal examination (DVE) is considered the standard of care for assessing labor progress and cervical dilatation. However, it may be painful and is a subjective method that can increase the risk of chorioamnionitis. Known inter- and intra-observer variability exists in measurements of cervical dilatation obtained digitally. However, little is known about the inter- and intra-observer variability when using intrapartum transperineal ultrasound (TPUS). Our objectives were to investigate the relationship between cervical dilatation as assessed by TPUS and DVE. To assess inter- and intra-observer variability in both single and repeated ultrasound assessments of cervical dilatation during active labor.
Material And Methods:
This single-center study was conducted at an inner-city maternity unit in London, UK. Nulliparous participants at term with a live, singleton fetus in cephalic presentation were recruited between May 2021 and November 2022. During active labor, TPUS was performed subsequent to DVE. Repeat ultrasound assessments were performed where feasible. Participants were in a supine position, with flexed hips and knees and with an empty bladder. The ultrasound transducer was placed transversely on the maternal perineum. The anteroposterior (AP) diameter of the cervix was measured, and two-dimensional (2D) cine-loop videos were analyzed to obtain accurate measurements. Data were excluded if the time difference between DVE and TPUS exceeded 60 min.
Results:
Of the 206 participants who consented to the study, complete data were obtained from 110 participants, yielding 147 paired TPUS and DVE observations. Ninety-six participants were excluded. The absolute difference between TPUS and DVE assessments was 0 cm in 34% of the observations, 1 cm in 46.3%, and between 2 and 4 cm in 19.7%. The mean difference was -0.9 cm (intraclass correlation coefficient = 0.85; p < 0.001). Data from 30 participants, with 50 cervical dilatation measurements, were used to assess inter- and intra-observer variability. The mean difference for the first ultrasound assessment was 0.07 cm (95% limit of agreement = -0.96 to 1.10, p < 0.001), for inter-observer variability, and 0.01 cm (95% limit of agreement = -0.29 to 0.30; p < 0.001) for intra-observer variability.
Conclusions:
Assessment of the cervix with TPUS during active labor is feasible and shows a strong correlation with DVE measurements. The majority of ultrasound measurements yielded readings within 1 cm of the corresponding DVE values, demonstrating high intraclass correlation and good inter- and intra-observer agreement.
Related Concept Videos
Perception of Sound Waves
The pitch of a sound depends on the frequency and the pressure amplitude of the source. Two sounds of the same...
Sound Waves: Interference
Shock Waves
When the source's speed approaches the speed of sound, constructive interference between successive wavefronts emitted by the source occurs immediately behind it. Initially, scientists believed that this constructive interference would result in such high...
Sound as Pressure Waves
The pressure fluctuation depends on the difference in displacements between the successive points in the...
Echo
Imagine the sound is reflected back to the ears. Assuming that the source is very close to the human, the difference between hearing the two sounds—the emitted sound and the reflected sound—may be more than the minimum time for perceiving distinct sounds. If this is the case,...
Ultrasound I: Abdominal Ultrasonography
Abdominal ultrasonography, commonly known as abdominal ultrasound, is a vital, non-invasive medical imaging technique widely used in healthcare.
Procedure:
This diagnostic tool allows the clinician to visually inspect internal structures within the abdomen, including vital organs such as the liver, gallbladder, pancreas, kidneys, and spleen.
The abdominal ultrasound process begins with applying a special gel to the patient's skin over the abdomen. This gel enhances the...