Ultrasound guided ultra-minimally invasive long head of the biceps tendon release: Anatomic and cadaver study
Guillermo Rodríguez-Maruri1, Jose Manuel Rojo-Manaute2, Lucia Lavin-Alconero3,4
1Department of Rehabilitation, Area V, Servicio de Salud del Principado de Asturias, SESPA, Gijón, Spain.
Purpose:
The aim of this study was to describe in volunteers and cadavers the location of the vascular structures at risk for performing a new safe and effective ultra-minimally invasive ultrasound guided long head of the biceps tendon (LHBT) release.
Methods:
First, with Doppler ultrasound, we defined the position of the acromial artery from our distal cutting point, on the posterior margin of the LHBT. Second, we performed an ultra-minimally invasive ultrasound guided LHBT release in cadavers. We described the stump and reported safety (no rotator cuff, vascular, or articular damages) and efficacy (tendon release rate).
Results:
In 20 volunteers, the mean distance from the distal cutting point to the acromial artery was 0.9 ± 0.1 cm (range, 0.3-1.6). Ultra-minimally invasive LHBT release was safe and fully effective in the eight specimens. The proximal stump measured a mean of 2.8 cm (range, 1.9-4). There were no complications.
Conclusions:
A safe and effective ultra-minimally invasive ultrasound guided LHBT release in cadavers is feasible through an anterior approach.