The Micturition Reflex01:26

The Micturition Reflex

502
Urination, or micturition involves the coordination of the bladder's detrusor muscle and two sphincters to ensure controlled bladder emptying.
The process begins with bladder filling, where the bladder wall stretches as urine accumulates. This stretching activates the urine storage reflex, mediated by the sacral spinal segments and the pontine storage center. Efferent sympathetic impulses stimulate the detrusor muscle to relax and the internal urethral sphincter to contract, facilitating...
502
Inflammatory Bowel Disease V: Surgical Management01:21

Inflammatory Bowel Disease V: Surgical Management

128
Surgical interventions for inflammatory bowel disease (IBD), which includes ulcerative colitis and Crohn's disease, are essential in managing symptoms and addressing complications. The selection of surgical procedures is contingent upon the specific conditions and complications that stem from these illnesses.
Here are some common surgical interventions for IBD:
128

You might also read

Related Articles

Articles linked to this work by shared authors, journal, and citation graph.

Sort by
Same author

Readability of sexual health educational materials: a comparative analysis of ISSM resources and large language model-generated content.

The journal of sexual medicine·2026
Same author

Emergency management of ureteral stones with SWL: is there any advantage over elective approach?

BMC urology·2026
Same author

Closing the Gap in Erectile Dysfunction Evaluation: Practical Insights for the Frontline Urologist.

The world journal of men's health·2026
Same author

Uncovering fertility potential: Clinical and histopathological insights from testicular biopsies in azoospermic men in a large Indonesian cohort.

F1000Research·2026
Same author

LuminaConsent: AI-driven standardization and quality enhancement of urological informed consent documentation.

Northern clinics of Istanbul·2026
Same author

Histopathological changes in the olfactory pathway in COVID-19: An autopsy-based case-control study.

Irish journal of medical science·2026

Related Experiment Video

Updated: Jun 13, 2025

Transcorporal Artificial Urinary Sphincter Cuff Placement in a Case Requiring Revision for Urethral Atrophy
03:25

Transcorporal Artificial Urinary Sphincter Cuff Placement in a Case Requiring Revision for Urethral Atrophy

Published on: June 16, 2022

905

Rigicon ContiClassic and ContiReflex artificial urinary sphincter devices.

Orhan Koca1, Rasim Güzel1, Duygu Kırkık2

  • 1Department of Urology, Medistate Hospital, Istanbul, Turkey.

Translational Andrology and Urology
|September 16, 2024
PubMed
Summary

The AMS 800 artificial urinary sphincter (AUS) has limitations. New Rigicon AUS devices, ContiClassic and ContiReflex, aim to improve outcomes for male stress urinary incontinence with enhanced designs.

Keywords:
Artificial urinary sphincter (AUS)device designstress urinary incontinence (SUI)technology advances

More Related Videos

Retzius-Sparing Robot-Assisted Radical Prostatectomy
12:10

Retzius-Sparing Robot-Assisted Radical Prostatectomy

Published on: May 19, 2022

7.6K
Cystometric and External Urethral Sphincter Measurements in Awake Rats with Implanted Catheter and Electrodes Allowing for Repeated Measurements
10:07

Cystometric and External Urethral Sphincter Measurements in Awake Rats with Implanted Catheter and Electrodes Allowing for Repeated Measurements

Published on: January 30, 2018

15.9K

Related Experiment Videos

Last Updated: Jun 13, 2025

Transcorporal Artificial Urinary Sphincter Cuff Placement in a Case Requiring Revision for Urethral Atrophy
03:25

Transcorporal Artificial Urinary Sphincter Cuff Placement in a Case Requiring Revision for Urethral Atrophy

Published on: June 16, 2022

905
Retzius-Sparing Robot-Assisted Radical Prostatectomy
12:10

Retzius-Sparing Robot-Assisted Radical Prostatectomy

Published on: May 19, 2022

7.6K
Cystometric and External Urethral Sphincter Measurements in Awake Rats with Implanted Catheter and Electrodes Allowing for Repeated Measurements
10:07

Cystometric and External Urethral Sphincter Measurements in Awake Rats with Implanted Catheter and Electrodes Allowing for Repeated Measurements

Published on: January 30, 2018

15.9K

Area of Science:

  • Urology
  • Biomedical Engineering
  • Medical Devices

Background:

  • The AMS 800 artificial urinary sphincter (AUS) is a standard treatment for male stress urinary incontinence.
  • Existing AMS 800 devices have limitations affecting clinical utility and outcomes.

Purpose of the Study:

  • To evaluate the design and technology of the new Rigicon ContiClassic and ContiReflex artificial urinary sphincter (AUS) devices.
  • To explore how these new devices aim to overcome limitations of the AMS 800.

Main Methods:

  • Review of the design features of the Rigicon ContiClassic and ContiReflex AUS devices.
  • Comparison of the new Rigicon devices with the established AMS 800.

Main Results:

  • The ContiClassic features a hydrophilic coating, expanded cuff size options, and tool-free connectors.
  • The ContiReflex includes an additional stress relief balloon (SRB) and a larger pump system for enhanced protection and fluid cycling.

Conclusions:

  • Rigicon's ContiClassic and ContiReflex AUS devices offer design advancements over the AMS 800.
  • These innovations aim to enhance the clinical performance and patient outcomes for artificial urinary sphincter therapy.